Two cases, one assigning to a slice.
Closes https://github.com/micropython/micropython/issues/13283
Second is extending a slice from itself, similar logic.
In both cases the problem occurs when m_renew causes realloc to move the
buffer, leaving a dangling pointer behind.
There are more complex and hard to fix cases when either argument is a
memoryview into the buffer, currently resizing to a new address breaks
memoryviews into that object.
Reproducing this bug and confirming the fix was done by running the unix
port under valgrind with GC-aware extensions.
Note in default configurations with GIL this bug exists but has no impact
(the free buffer won't be reused while the function is still executing, and
is no longer referenced after it returns).
Signed-off-by: Angus Gratton <angus@redyak.com.au>
This commit swaps the order of the `flags` and `name` struct initialisers
for `mp_obj_type_t`, to fix an incompatibility with C++. The original
order of the initialiser didn't match the definition of the type, and
although that's still legal C, it's not legal C++.
Signed-off-by: Vonasmic <kasarkal123@gmail.com>
When `lightsleep()` is called from within a thread the interrupts may not
be enabled on current core, and thus the call to `lightsleep()` never
completes.
Fixes issue #14092.
Signed-off-by: Simon Wood <simon@mungewell.org>
In the case where an OUT control transfer triggers with wLength==0 (i.e.
all data sent in the SETUP phase, and no additional data phase) the
callbacks were previously implemented to return b"" (i.e. an empty buffer
for the data phase).
However this didn't actually work as intended because b"" can't provide a
RW buffer (needed for OUT transfers with a data phase to write data into),
so actually the endpoint would stall.
The symptom was often that the device process the request (if processing
it in the SETUP phase when all information was already available), but the
host sees the endpoint stall and eventually returns an error.
This commit changes the behaviour so returning True from the SETUP phase of
a control transfer queues a zero length status response.
Signed-off-by: Angus Gratton <angus@redyak.com.au>
This optimises the case where a Python function is, for example, stored to
a JavaScript attribute and then later retrieved from Python. The Python
function no longer needs to be a proxy with double proxying needed for the
call from Python -> JavaScript -> Python.
Signed-off-by: Damien George <damien@micropython.org>
Use the existing metal log handling mechanism instead of overriding the
metal_log, which causes build issues when logging is enabled.
Signed-off-by: iabdalkader <i.abdalkader@gmail.com>
Ports that use axtls cannot run the `test_tls_sites.py` test because the
sites it connects to use advanced ciphers. So skip this test on such
ports, and add a new, simpler test that doesn't require certificate
verification and works with axtls.
Signed-off-by: Damien George <damien@micropython.org>
Supporting `verify_mode` and `CERT_NONE` is required for the new `ssl.py`
code, as well as `requests` to work.
Signed-off-by: Damien George <damien@micropython.org>
This is required because the .mpy native ABI was changed by the
introduction of `mp_proto_fun_t`, see commits:
- 416465d81e
- 5e3006f117
- e2ff00e811
And three `mp_binary` functions were added to `mp_fun_table` in
commit d2276f0d41.
Signed-off-by: Damien George <damien@micropython.org>
These are needed to read/write array.array objects, which is useful in
native code to provide fast extensions that work with big arrays of data.
Signed-off-by: Damien George <damien@micropython.org>
Change provided by @ironss-iotec.
Tested with Adafruit, SEEED and MiniFig boards for non-interference.
Fixes issue #14190.
Signed-off-by: robert-hh <robert@hammelrath.com>
Using a define for MICROPY_HW_SPIFLASH_BAUDRATE in mpconfigboard.h. If not
defined the default is 24MHz.
Signed-off-by: robert-hh <robert@hammelrath.com>
For all MCUs: run the test for USB clock recovery mode fallback after USB
has been started.
For samd21: change DFLL48 config from the open loop mode variant to sync
with the XOSC32KULP. Matches better the 48MHz value.
Signed-off-by: robert-hh <robert@hammelrath.com>
Other constants such as `machine.Pin.OUT` are defined on the class that
uses them, rather than at the module level. This commit makes that the
case for WLAN network interfaces, adding IF_xxx and SEC_xxx constants.
The SEC_xxx constants are named as such to match the `security` keyword
that they are used with. And the IF_xxx constants have IF as a prefix so
they are grouped together as names.
This scheme of putting constants on the class means that only the available
features (eg security configurations) are made available as constants. It
also means that different network interfaces (eg WLAN vs LAN) can keep
their own specific constants within their class, such as PHY_xxx for LAN.
Signed-off-by: iabdalkader <i.abdalkader@gmail.com>
The default CYW43 WiFi AP settings were missing the security mode, leaving
the AP in open mode by default. That's changed by this commit to use
WPA/WPA2 by default.
Signed-off-by: iabdalkader <i.abdalkader@gmail.com>
When defining custom USB devices, longer strings may be needed. Eventually
the memory for string descriptors can be allocated on demand, but for now
this bigger value should be reasonable.
Signed-off-by: Damien George <damien@micropython.org>
Updates a few code comments that were out of date or poorly worded. No code
changes.
This work was funded through GitHub Sponsors.
Signed-off-by: Angus Gratton <angus@redyak.com.au>
Previously, constructing the singleton USBDevice object was enough to
trigger a USB disconnect on soft reset. Now it also has to be active.
The only case where this changes the behaviour is if the USBDevice object
has been constructed but never set to active (no more disconnect in this
case). Otherwise, behaviour is the same.
This change was requested by hippy on the raspberrypi forums.
This work was funded through GitHub Sponsors.
Signed-off-by: Angus Gratton <angus@redyak.com.au>
When PWM constructor was created without specifying a device or setting
both freq and duty rate, it was not tagged as used, and further calls to
get a PWM object may get the same PWM device assigned.
Fixes#13494.
Signed-off-by: robert-hh <robert@hammelrath.com>