@ -241,6 +241,16 @@ void packet_tx_handler(void) {
case BME280_QF_HUMIDITY_DEGRADED:
case BME280_QF_GEN_DEGRADED: humidity_qf = HUMIDITY_QF_DEGRADATED; break;
}
switch (rte_wx_bme280_qf) {
case BME280_QF_FULL:
case BME280_QF_HUMIDITY_DEGRADED: pressure_qf = PRESSURE_QF_FULL; break;
case BME280_QF_UKNOWN:
case BME280_QF_NOT_AVAILABLE: pressure_qf = PRESSURE_QF_NOT_AVALIABLE; break;
case BME280_QF_PRESSURE_DEGRADED:
case BME280_QF_GEN_DEGRADED: pressure_qf = PRESSURE_QF_DEGRADATED; break;
}
}
#else
pressure_qf = PRESSURE_QF_NOT_AVALIABLE;

Wyświetl plik

@ -148,7 +148,7 @@ void wx_get_all_measurements(void) {
// converting raw values to temperature
bme280_get_temperature(&rte_wx_temperature_ms, bme280_get_adc_t(), &rte_wx_bme280_qf);
// if modbus RTU is enabled but the quality factor for RTU-pressure is set to non FULL
// if modbus RTU is enabled but the quality factor for RTU-pressure is set to NOT_AVALIABLE
if ((modbus_qf & MODBUS_QF_PRESSURE_FULL) == 0 && (modbus_qf & MODBUS_QF_PRESSURE_DEGR) == 0) {
// converting raw values to pressure
bme280_get_pressure(&rte_wx_pressure, bme280_get_adc_p(), &rte_wx_bme280_qf);
@ -157,7 +157,7 @@ void wx_get_all_measurements(void) {
;
}
// if modbus RTU is enabled but the quality factor for RTU-humidity is set to non FULL
// if modbus RTU is enabled but the quality factor for RTU-humidity is set to NOT_AVALIABLE
if ((modbus_qf & MODBUS_QF_HUMIDITY_FULL) == 0 && (modbus_qf & MODBUS_QF_HUMIDITY_DEGR) == 0) {
// converting raw values to humidity
bme280_get_humidity(&rte_wx_humidity, bme280_get_adc_h(), &rte_wx_bme280_qf);