kopia lustrzana https://github.com/SP8EBC/ParaTNC
wrong operator priorites
rodzic
de7fcbb432
commit
da29b5c8a6
|
@ -5,7 +5,7 @@
|
|||
#include "drivers/serial.h"
|
||||
|
||||
#define SW_VER "DF13"
|
||||
#define SW_DATE "11032021"
|
||||
#define SW_DATE "12032021"
|
||||
|
||||
#define SYSTICK_TICKS_PER_SECONDS 100
|
||||
#define SYSTICK_TICKS_PERIOD 10
|
||||
|
|
|
@ -124,7 +124,7 @@ void wx_get_all_measurements(void) {
|
|||
#endif
|
||||
#endif
|
||||
|
||||
#if (!defined(_UMB_MASTER) && !defined(_DAVIS_SERIAL) && !defined(_MODBUS_RTU) && defined (_SENSOR_MS5611)) || (defined (_SENSOR_MS5611) && defined (_MODBUS_RTU) && !defined(_RTU_SLAVE_PRESSURE_SOURCE))
|
||||
#if (!defined(_UMB_MASTER) && !defined(_DAVIS_SERIAL) && !defined(_MODBUS_RTU) && defined (_SENSOR_MS5611)) || (defined (_SENSOR_MS5611) && defined (_MODBUS_RTU))
|
||||
// quering MS5611 sensor for temperature
|
||||
return_value = ms5611_get_temperature(&rte_wx_temperature_ms, &rte_wx_ms5611_qf);
|
||||
|
||||
|
@ -149,7 +149,7 @@ void wx_get_all_measurements(void) {
|
|||
bme280_get_temperature(&rte_wx_temperature_ms, bme280_get_adc_t(), &rte_wx_bme280_qf);
|
||||
|
||||
// if modbus RTU is enabled but the quality factor for RTU-pressure is set to non FULL
|
||||
if ((modbus_qf & MODBUS_QF_PRESSURE_FULL == 0) && (modbus_qf & MODBUS_QF_PRESSURE_DEGR == 0)) {
|
||||
if ((modbus_qf & MODBUS_QF_PRESSURE_FULL) == 0 && (modbus_qf & MODBUS_QF_PRESSURE_DEGR) == 0) {
|
||||
// converting raw values to pressure
|
||||
bme280_get_pressure(&rte_wx_pressure, bme280_get_adc_p(), &rte_wx_bme280_qf);
|
||||
}
|
||||
|
@ -158,7 +158,7 @@ void wx_get_all_measurements(void) {
|
|||
}
|
||||
|
||||
// if modbus RTU is enabled but the quality factor for RTU-humidity is set to non FULL
|
||||
if ((modbus_qf & MODBUS_QF_HUMIDITY_FULL == 0) && (modbus_qf & MODBUS_QF_HUMIDITY_DEGR == 0)) {
|
||||
if ((modbus_qf & MODBUS_QF_HUMIDITY_FULL) == 0 && (modbus_qf & MODBUS_QF_HUMIDITY_DEGR) == 0) {
|
||||
// converting raw values to humidity
|
||||
bme280_get_humidity(&rte_wx_humidity, bme280_get_adc_h(), &rte_wx_bme280_qf);
|
||||
}
|
||||
|
@ -172,14 +172,14 @@ void wx_get_all_measurements(void) {
|
|||
rte_wx_temperature_ms_valid = rte_wx_temperature_ms;
|
||||
|
||||
// if modbus RTU is enabled but the quality factor for RTU-humidity is set to non FULL
|
||||
if ((modbus_qf & MODBUS_QF_HUMIDITY_FULL == 0) && (modbus_qf & MODBUS_QF_HUMIDITY_DEGR == 0)) {
|
||||
if ((modbus_qf & MODBUS_QF_HUMIDITY_FULL) == 0 && (modbus_qf & MODBUS_QF_HUMIDITY_DEGR) == 0) {
|
||||
rte_wx_humidity_valid = rte_wx_humidity;
|
||||
}
|
||||
else {
|
||||
; // if humidity was obtained from RTU sensor use that value and do not bother with BME280
|
||||
}
|
||||
|
||||
if ((modbus_qf & MODBUS_QF_PRESSURE_FULL == 0) && (modbus_qf & MODBUS_QF_PRESSURE_DEGR == 0)) {
|
||||
if ((modbus_qf & MODBUS_QF_PRESSURE_FULL) == 0 && (modbus_qf & MODBUS_QF_PRESSURE_DEGR) == 0) {
|
||||
rte_wx_pressure_valid = rte_wx_pressure;
|
||||
|
||||
// add the current pressure into buffer
|
||||
|
@ -278,11 +278,11 @@ void wx_get_all_measurements(void) {
|
|||
wx_inhibit_slew_rate_check = 0;
|
||||
#endif
|
||||
|
||||
#if (!defined(_UMB_MASTER) && !defined(_DAVIS_SERIAL) && !defined(_MODBUS_RTU) && defined (_SENSOR_MS5611)) || (defined (_SENSOR_MS5611) && defined (_MODBUS_RTU) && !defined(_RTU_SLAVE_PRESSURE_SOURCE))
|
||||
#if (!defined(_UMB_MASTER) && !defined(_DAVIS_SERIAL) && !defined(_MODBUS_RTU) && defined (_SENSOR_MS5611)) || (defined (_SENSOR_MS5611) && defined (_MODBUS_RTU))
|
||||
// quering MS5611 sensor for pressure
|
||||
return_value = ms5611_get_pressure(&rte_wx_pressure, &rte_wx_ms5611_qf);
|
||||
|
||||
if (return_value == MS5611_OK) {
|
||||
if (return_value == MS5611_OK && (modbus_qf & MODBUS_QF_PRESSURE_FULL) == 0 && (modbus_qf & MODBUS_QF_PRESSURE_DEGR) == 0) {
|
||||
// add the current pressure into buffer
|
||||
rte_wx_pressure_history[rte_wx_pressure_it++] = rte_wx_pressure;
|
||||
|
||||
|
|
Ładowanie…