sane-project-website/unsupported/genius-colorpage-hr8.html

221 wiersze
6.7 KiB
HTML

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<html>
<head>
<title>Scanner information</title>
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
<meta name="author" content="Henning Meier-Geinitz">
<meta name="keywords" content="sane, backend, driver, scanner, unsupported">
<link href="mailto:henning@meier-geinitz.de" rev="made">
<link rel="icon" href="../favicon.ico" type="image/x-icon">
<link rel="shortcut icon" href="../favicon.ico" type="image/x-icon">
</head>
<body>
<h1>Scanners not supported by SANE</h1>
<h2>Manufacturer and model</h2>
<p>
Genius ColorPage HR8
</p>
<h2>Bus type</h2>
<p>
USB
</p>
<h2>Vendor ID</h2>
<p>
0x0458
</p>
<h2>Product ID</h2>
<p>
0x201c
</p>
<h2>Chipset</h2>
<p>
Uses a <a
href="http://www.genesyslogic.com/econtents/product02.asp?SN=48&minicidx=3&lastcidx=18">GL841
chipset</a>
</p>
<h2>Comments</h2>
<p>
The specifications say, that it's "Super CCD". Probably made by FUJI since
Super CCD is their invention. The HR8 has 2400 dpi resolution with
transparency film scanner.
</p>
<p>
This scanner may be supported by the <a
href="http://www.meier-geinitz.de/sane/genesys-backend/">Genesys backend</a>, when it's
finished.
</p>
<p>
2400x2400 dpi. Similar to Plustek ST48?
</p>
<h2>Output of /proc/bus/usb/devices or sane-find-scanner -v -v</h2>
<pre>
CP-HR8
Manufacturer: KYE CORP
Speed: 480Mb/s (high)
USB Version: 2.00
Device Class: ff(vend.)
Device Subclass: ff
Device Protocol: ff
Maximum Default Endpoint Size: 64
Number of Configurations: 1
Vendor Id: 0458
Product Id: 201c
Revision Number: 3.03
Config Number: 1
Number of Interfaces: 1
Attributes: c0
MaxPower Needed: 10mA
Interface Number: 0
Name: (none)
Alternate Number: 0
Class: ff(vend.)
Sub Class: 0
Protocol: 0
Number of Endpoints: 3
Endpoint Address: 81
Direction: in
Attribute: 2
Type: Bulk
Max Packet Size: 512
Interval: 0ms
Endpoint Address: 02
Direction: out
Attribute: 2
Type: Bulk
Max Packet Size: 512
Interval: 0ms
Endpoint Address: 83
Direction: in
Attribute: 3
Type: Int.
Max Packet Size: 1
Interval: 16ms
&lt;device descriptor of 0x0458/0x201c at 003:003 (KYE CORP CP-HR8)&gt;
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 255
bDeviceSubClass 255
bDeviceProtocol 255
bMaxPacketSize0 64
idVendor 0x0458
idProduct 0x201C
bcdDevice 3.03
iManufacturer 2 (KYE CORP)
iProduct 3 (CP-HR8)
iSerialNumber 0 ()
bNumConfigurations 1
&lt;configuration 0&gt;
bLength 9
bDescriptorType 2
wTotalLength 39
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 0 ()
bmAttributes 192 (Self-powered)
MaxPower 10 mA
&lt;interface 0&gt;
&lt;altsetting 0&gt;
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 3
bInterfaceClass 255
bInterfaceSubClass 255
bInterfaceProtocol 255
iInterface 0 ()
&lt;endpoint 0&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x81 (in 0x01)
bmAttributes 2 (bulk)
wMaxPacketSize 64
bInterval 0 ms
bRefresh 0
bSynchAddress 0
&lt;endpoint 1&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x02 (out 0x02)
bmAttributes 2 (bulk)
wMaxPacketSize 64
bInterval 0 ms
bRefresh 0
bSynchAddress 0
&lt;endpoint 2&gt;
bLength 7
bDescriptorType 5
bEndpointAddress 0x83 (in 0x03)
bmAttributes 3 (interrupt)
wMaxPacketSize 1
bInterval 8 ms
bRefresh 0
bSynchAddress 0
&lt;trying to find out which USB chip is used&gt;
checking for GT-6801 ...
this is not a GT-6801 (bcdUSB = 0x200)
checking for GT-6816 ...
this is not a GT-6816 (bDeviceClass = 255, bInterfaceClass = 255)
checking for MA-1017 ...
this is not a MA-1017 (bDeviceClass = 255, bInterfaceClass = 255)
checking for MA-1015 ...
this is not a MA-1015 (bcdUSB = 0x200)
checking for MA-1509 ...
this is not a MA-1509 (bcdUSB = 0x200)
checking for LM983[1,2,3] ...
this is not a LM983x (bcdUSB = 0x200)
checking for GL646 ...
this is not a GL646 (bDeviceClass = 255, bInterfaceClass = 255)
checking for GL660+GL646 ...
this is not a GL660+GL646 (bDeviceClass = 255, bInterfaceClass = 255)
&lt;Couldn't determine the type of the USB chip&gt;
found USB scanner (vendor=0x0458 [KYE CORP], product=0x201c [CP-HR8]) at libusb:003:003
</pre>
<h1>Want to add or correct information?</h1>
<p>
If anything is wrong or missing on this page please <a href="../bugs.html">file a bug report</a>
or use the <a href="http://www.meier-geinitz.de:80/tinc?key=rDoQ7lrj&#38;formname=adddev" target="_top">the
form for adding an unsupported device</a>.
</p>
<p>
If you own an unsupported scanner, please send as much information as
possible. Especially the output of <em>sane-find-scanner -v -v</em>
and/or <em>cat /proc/scsi/scsi</em> (for SCSI scanners) or <em>cat
/proc/bus/usb/devices</em> (for USB scanners) can help. If you dare to
open the scanner, have a look at the text that's printed on the
chips. That may help to identify the chipset. If you know that the
scanner is similar to another one (e.g. supported by the same Windows
driver), please also mention this fact.
</p>
<h1><a href="../manufacturers.html">Information for Manufacturers</a></h1>
<p>
Are you a manufacturer or vendor of scanners and one of your scanners is
not supported by SANE yet? In this case please have a look at our <a
href="../manufacturers.html">information for manufacturers</a>.
</p>
<hr>
<p>
<a href="../">SANE homepage</a><br>
<a href="../imprint.html">Contact</a>
</p>
</body>
</html>