<TITLE>sane-devel: Problem with Microtek 35t slide/negative scanner</TITLE>
<META NAME="Author" CONTENT="Daniel Luechtefeld (wolucky@yahoo.com)">
<META NAME="Subject" CONTENT="Problem with Microtek 35t slide/negative scanner">
</HEAD>
<BODY BGCOLOR="#FFFFFF" TEXT="#000000">
<H1>Problem with Microtek 35t slide/negative scanner</H1>
<!-- received="Fri May 25 01:23:31 2001" -->
<!-- isoreceived="20010525082331" -->
<!-- sent="Fri, 25 May 2001 01:26:26 -0700 (PDT)" -->
<!-- isosent="20010525082626" -->
<!-- name="Daniel Luechtefeld" -->
<!-- email="wolucky@yahoo.com" -->
<!-- subject="Problem with Microtek 35t slide/negative scanner" -->
<!-- id="20010525082626.5265.qmail@web11501.mail.yahoo.com" -->
<STRONG>From:</STRONG> Daniel Luechtefeld (<A HREF="mailto:wolucky@yahoo.com?Subject=Re:%20Problem%20with%20Microtek%2035t%20slide/negative%20scanner&In-Reply-To=&lt;20010525082626.5265.qmail@web11501.mail.yahoo.com&gt;"><EM>wolucky@yahoo.com</EM></A>)<BR>
<STRONG>Date:</STRONG> Fri May 25 2001 - 01:26:26 PDT
<P>
<!-- next="start" -->
<LI><STRONG>Next message:</STRONG> <A HREF="0337.html">Oliver Rauch: "Re: [BUG] Epson 1640SU, xsane preview problem]"</A>
<UL>
<LI><STRONG>Previous message:</STRONG> <A HREF="0335.html">Oliver Rauch: "sane-net/saned problems solved?!"</A>
<!-- nextthread="start" -->
<LI><STRONG>Next in thread:</STRONG> <A HREF="0338.html">Jonathan Buzzard: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<LI><STRONG>Reply:</STRONG> <A HREF="0338.html">Jonathan Buzzard: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<LI><STRONG>Reply:</STRONG> <A HREF="0340.html">Matto Marjanovic: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<LI><STRONG>Reply:</STRONG> <A HREF="0371.html">EdHamrick@aol.com: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<!-- reply="end" -->
<LI><STRONG>Messages sorted by:</STRONG>
<A HREF="date.html#336">[ date ]</A>
<A HREF="index.html#336">[ thread ]</A>
<A HREF="subject.html#336">[ subject ]</A>
<A HREF="author.html#336">[ author ]</A>
</UL>
<HR NOSHADE><P>
<!-- body="start" -->
<P>
Hi,
<BR>
<P>First off, thanks to the SANE development team for your
<BR>
contributions
<BR>
to the Linux community. I'm an amateur photographer and Unix
<BR>
sysadmin (Solaris) who'd have to give up running Linux at home were
<BR>
it not for your work on scanners.
<BR>
<P>Now then...my Microtek 35t (PTS1800S) slide scanner doesn't work
<BR>
anymore since upgrading from a Caldera 2.2.x distro to a Mandrake
<BR>
2.4.22-mdk. The SCSI host adapter is a DPT SmartCache III using the
<BR>
EATA 2.0c driver.
<BR>
<P>I'm running sane-backends-1.0.4 and sane-frotends-1.0.4. I've
<BR>
applied sg timeout patch to sane-backends-1.0.4 that was described
<BR>
on the list a few weeks ago:
<BR>
<P>req-&gt;sgdata.sg3.hdr.timeout = 10000 * 10 * 60
<BR>
<P><P>&quot;xscanimage&quot; successfully finds the scanner at /dev/scanner, which
<BR>
is linked to /dev/sga. xscanimage then initializes the scanner,
<BR>
which begins going through the approximate 30-second process of
<BR>
scanning the negative tray. However, before the scanner completes
<BR>
the scan, xscanimage issues a &quot;Device Busy: Couldn't start scanner&quot;
<BR>
dialog box.
<BR>
After this happens, &quot;scanimage -L&quot; and &quot;find-scanner&quot; fail to detect
<BR>
the scanner until I reboot.
<BR>
<P>Attached to this email is a debug session. Thanks again for your
<BR>
help.
<BR>
<P><P>=====
<BR>
Lowrider
<BR>
<P>__________________________________________________
<BR>
Do You Yahoo!?
<BR>
Yahoo! Auctions - buy the things you want at great prices
<BR>
<A HREF="http://auctions.yahoo.com/">http://auctions.yahoo.com/</A>
<BR>
<BR><P>
[sanei_debug] Setting debug level of microtek to 256.
<BR>
[microtek] sane_init: MICROTEK says hello! (v0.12.1)
<BR>
[microtek] sane_init: config- # Uncomment following line to disable &quot;real calibration&quot; routines...[microtek] sane_init: config- #norealcal[microtek] sane_init: config- # Uncomment following line to disable &quot;clever precalibration&quot; routines...[microtek] sane_init: config- #noprecal[microtek] sane_init: config- # Using &quot;norealcal&quot; will revert backend to pre-0.11.0 calibration code.[microtek] sane_init: config- scsi * * Scanner[microtek] attach_scanner: /dev/sga
<BR>
[microtek] attach_scanner: opening /dev/sga
<BR>
[microtek] attach_scanner: sending INQUIRY
<BR>
[microtek] id_microtek...
<BR>
[microtek] parse_inquiry...
<BR>
[microtek] parse_inquiry: Not an E6 -- pretend recal cannot be disabled.
<BR>
[microtek] dump_inquiry...
<BR>
&nbsp;=== SANE/Microtek backend v0.12.1 ===
<BR>
========== Scanner Inquiry Block ========mm
<BR>
06 31 10 01 5b 00 00 00 4d 49 43 52 4f 54 45 4b
<BR>
50 54 53 31 38 30 30 53 20 53 43 41 4e 4e 45 52
<BR>
31 2e 30 35 53 43 53 49 20 46 2f 57 56 33 2e 31
<BR>
20 43 54 4c 35 33 38 30 03 2f 8c c2 82 ee 52 00
<BR>
01 01 01 00 00 00 00 01 0e ff 00 00 00 00 00 00
<BR>
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ff
<BR>
<P>========== Scanner Inquiry Report ==========
<BR>
===== Scanner ID...
<BR>
Device Type Code: 0x06
<BR>
Model Code: 0x52
<BR>
Vendor Name: 'MICROTEK' Model Name: 'PTS1800S SCANNER'
<BR>
Vendor Specific String: 'SCSI F/WV3.1 CTL5380'
<BR>
Firmware Rev: '1.05'
<BR>
SCSI F/W version: 3.1 Scanner F/W version: 1.0
<BR>
Response data format: 0x01
<BR>
===== Imaging Capabilities...
<BR>
Modes: Lineart Halftone Gray Color (X-msv)
<BR>
Resolution Step Sizes: 1% 5% Expanded Resolution Support? yes
<BR>
Supported Bits Per Sample: 8
<BR>
Max. document size code: 0x82
<BR>
Max. document size: 2589 x 2589 pixels
<BR>
Frame units: pixels 1/8&quot;'s
<BR>
# of built-in halftones: 12 Downloadable patterns? Yes
<BR>
Data Compression:
<BR>
Contrast Settings: 14 Exposure Settings: 14
<BR>
Adjustable Shadow/Highlight? yes Adjustable Midtone? no
<BR>
Digital brightness/offset? no
<BR>
Gamma Table Size: 256 entries of 1 bytes (max. depth: 8)
<BR>
===== Source Options...
<BR>
Feed type: edge-feed ADF support? no
<BR>
Document Feeder Support? no Feeder Backtracking? no
<BR>
Feeder Installed? no Feeder Ready? no
<BR>
Transparency Adapter Installed? no
<BR>
Fast Color Prescan? no
<BR>
Selectable Transfer Format? no
<BR>
Color Transfer Sequence: plane-by-plane (3-pass)
<BR>
Three pass scan support? yes
<BR>
ModeSelect-1 and ModeSense-1 Support? yes
<BR>
Can Disable Linearization Table? no
<BR>
Can Disable Start-of-Scan Recalibration? no
<BR>
Internal expanded expansion? no
<BR>
<P><P>[microtek] attach_scanner: happy.
<BR>
[microtek] attach_scanner: /dev/sga
<BR>
[microtek] sane_init: config- /dev/scanner[microtek] attach_scanner: /dev/scanner
<BR>
[microtek] attach_scanner: opening /dev/scanner
<BR>
[microtek] attach_scanner: sending INQUIRY
<BR>
[microtek] id_microtek...
<BR>
[microtek] parse_inquiry...
<BR>
[microtek] parse_inquiry: Not an E6 -- pretend recal cannot be disabled.
<BR>
[microtek] dump_inquiry...
<BR>
&nbsp;=== SANE/Microtek backend v0.12.1 ===
<BR>
========== Scanner Inquiry Block ========mm
<BR>
06 31 10 01 5b 00 00 00 4d 49 43 52 4f 54 45 4b
<BR>
50 54 53 31 38 30 30 53 20 53 43 41 4e 4e 45 52
<BR>
31 2e 30 35 53 43 53 49 20 46 2f 57 56 33 2e 31
<BR>
20 43 54 4c 35 33 38 30 03 2f 8c c2 82 ee 52 00
<BR>
01 01 01 00 00 00 00 01 0e ff 00 00 00 00 00 00
<BR>
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ff
<BR>
<P>========== Scanner Inquiry Report ==========
<BR>
===== Scanner ID...
<BR>
Device Type Code: 0x06
<BR>
Model Code: 0x52
<BR>
Vendor Name: 'MICROTEK' Model Name: 'PTS1800S SCANNER'
<BR>
Vendor Specific String: 'SCSI F/WV3.1 CTL5380'
<BR>
Firmware Rev: '1.05'
<BR>
SCSI F/W version: 3.1 Scanner F/W version: 1.0
<BR>
Response data format: 0x01
<BR>
===== Imaging Capabilities...
<BR>
Modes: Lineart Halftone Gray Color (X-msv)
<BR>
Resolution Step Sizes: 1% 5% Expanded Resolution Support? yes
<BR>
Supported Bits Per Sample: 8
<BR>
Max. document size code: 0x82
<BR>
Max. document size: 2589 x 2589 pixels
<BR>
Frame units: pixels 1/8&quot;'s
<BR>
# of built-in halftones: 12 Downloadable patterns? Yes
<BR>
Data Compression:
<BR>
Contrast Settings: 14 Exposure Settings: 14
<BR>
Adjustable Shadow/Highlight? yes Adjustable Midtone? no
<BR>
Digital brightness/offset? no
<BR>
Gamma Table Size: 256 entries of 1 bytes (max. depth: 8)
<BR>
===== Source Options...
<BR>
Feed type: edge-feed ADF support? no
<BR>
Document Feeder Support? no Feeder Backtracking? no
<BR>
Feeder Installed? no Feeder Ready? no
<BR>
Transparency Adapter Installed? no
<BR>
Fast Color Prescan? no
<BR>
Selectable Transfer Format? no
<BR>
Color Transfer Sequence: plane-by-plane (3-pass)
<BR>
Three pass scan support? yes
<BR>
ModeSelect-1 and ModeSense-1 Support? yes
<BR>
Can Disable Linearization Table? no
<BR>
Can Disable Start-of-Scan Recalibration? no
<BR>
Internal expanded expansion? no
<BR>
<P><P>[microtek] attach_scanner: happy.
<BR>
[microtek] sane_get_devices
<BR>
[microtek] sane_open
<BR>
[microtek] sane_open: find device...
<BR>
[microtek] sane_open: create scanner...
<BR>
[microtek] sane_open: initialize scanner dependent stuff...
<BR>
[microtek] sane_open: All calibration routines disabled.
<BR>
[microtek] sane_open: init gamma tables...
<BR>
[microtek] sane_open: init pass-time variables...
<BR>
[microtek] sane_open: init clever cache...
<BR>
[microtek] sane_open: initialize options:
<BR>
[microtek] init_options...
<BR>
[microtek] init_options: quant yes
<BR>
[microtek] init_options: done.
<BR>
[microtek] sane_control_option (opt=0,act=0,val=0xbffff494,info=(nil))
<BR>
[microtek] sane_control_option (opt=0,act=0,val=0xbffff448,info=(nil))
<BR>
[microtek] sane_get_option_descriptor (0)...
<BR>
[microtek] sane_get_option_descriptor (1)...
<BR>
[microtek] sane_get_option_descriptor (2)...
<BR>
[microtek] sane_get_option_descriptor (3)...
<BR>
[microtek] sane_get_option_descriptor (4)...
<BR>
[microtek] sane_get_option_descriptor (5)...
<BR>
[microtek] sane_get_option_descriptor (6)...
<BR>
[microtek] sane_get_option_descriptor (7)...
<BR>
[microtek] sane_get_option_descriptor (8)...
<BR>
[microtek] sane_get_option_descriptor (9)...
<BR>
[microtek] sane_get_option_descriptor (10)...
<BR>
[microtek] sane_get_option_descriptor (11)...
<BR>
[microtek] sane_get_option_descriptor (12)...
<BR>
[microtek] sane_get_option_descriptor (13)...
<BR>
[microtek] sane_get_option_descriptor (14)...
<BR>
[microtek] sane_control_option (opt=14,act=0,val=0x80505b8,info=(nil))
<BR>
[microtek] sane_get_option_descriptor (15)...
<BR>
[microtek] sane_control_option (opt=15,act=0,val=0x80505bc,info=(nil))
<BR>
[microtek] sane_get_option_descriptor (16)...
<BR>
[microtek] sane_get_option_descriptor (17)...
<BR>
[microtek] sane_get_option_descriptor (18)...
<BR>
[microtek] sane_get_option_descriptor (19)...
<BR>
[microtek] sane_get_option_descriptor (20)...
<BR>
[microtek] sane_get_option_descriptor (21)...
<BR>
[microtek] sane_get_option_descriptor (22)...
<BR>
[microtek] sane_get_option_descriptor (23)...
<BR>
[microtek] sane_get_option_descriptor (24)...
<BR>
[microtek] sane_get_option_descriptor (25)...
<BR>
[microtek] sane_get_option_descriptor (26)...
<BR>
[microtek] sane_get_option_descriptor (27)...
<BR>
[microtek] sane_get_option_descriptor (28)...
<BR>
[microtek] sane_get_option_descriptor (29)...
<BR>
[microtek] sane_get_option_descriptor (30)...
<BR>
[microtek] sane_get_option_descriptor (31)...
<BR>
[microtek] sane_get_option_descriptor (32)...
<BR>
[microtek] sane_get_option_descriptor (33)...
<BR>
[microtek] sane_control_option (opt=12,act=0,val=0xbffff444,info=(nil))
<BR>
[microtek] sane_control_option (opt=13,act=0,val=0xbffff444,info=(nil))
<BR>
[microtek] sane_control_option (opt=12,act=0,val=0xbffff490,info=(nil))
<BR>
[microtek] sane_get_option_descriptor (14)...
<BR>
[microtek] sane_control_option (opt=14,act=1,val=0xbffff48c,info=0xbffff448)
<BR>
[microtek] sane_control_option (opt=13,act=0,val=0xbffff490,info=(nil))
<BR>
[microtek] sane_get_option_descriptor (15)...
<BR>
[microtek] sane_control_option (opt=15,act=1,val=0xbffff48c,info=0xbffff448)
<BR>
[microtek] sane_start...
<BR>
[microtek] sane_get_parameters...
<BR>
[microtek] sane_get_parameters: regular 3-pass color
<BR>
[microtek] sane_get_parameters: res_code = 5 ( 5)
<BR>
[microtek] sane_get_parameters: dots_per_mm: 3.937008
<BR>
[microtek] sane_get_parameters: units_per_mm: 71.968504
<BR>
[microtek] WIDTHPIX: before exp: 140
<BR>
[microtek] sane_get_parameters: lines: 141 ppl: 140 bpl: 140
<BR>
[microtek] set_pass_parameters: three-pass, on 1
<BR>
[microtek] .wait_ready 31...
<BR>
[microtek] finagle_precal...
<BR>
[microtek] .scanning_frame...
<BR>
[microtek] .scanning_frame: in- 0,0 2589,2589
<BR>
[microtek] .scanning_frame: out- 0,0 2589,2589
<BR>
SF: 4 0 0 0 9 0 8 0 0 0 0 1d a 1d a
<BR>
[microtek] .download_gamma...
<BR>
[microtek] .download_gamma: 256 entries of 1 bytes, max 255
<BR>
[microtek] .download_gamma: by default
<BR>
[microtek] .mode_select 31...
<BR>
[microtek] .mode_select: pap_len: 2589
<BR>
MSL: 15 0 0 0 a 0 8b 5 7 7 0 1 0 ff 1d a
<BR>
[microtek] .mode_select_1 31...
<BR>
MSL1: 16 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0
<BR>
[microtek] .wait_ready 31...
<BR>
[microtek] .start_scan...
<BR>
SS: 1b 0 0 0 49 0
<BR>
[microtek] .get_scan_status 31...
<BR>
[microtek] get_scan_status(6): 0, 128, 129 -&gt; #0
<BR>
[microtek] &gt; 0 80 0 81 0 0
<BR>
[microtek] Scan Param:
<BR>
[microtek] pix bpl: 128 hdr bpl: 0 ppl: 128
<BR>
[microtek] undel bytes: 16512 unscan lines: 129 planes: 1
<BR>
[microtek] dest bpl: 128 dest ppl: 128 aspect: 1.000000
<BR>
[microtek] sane_get_parameters...
<BR>
[microtek] sane_read...
<BR>
[microtek] read_from_scanner...
<BR>
[microtek] .get_scan_status 31...
<BR>
[microtek] get_scan_status(6): 0, 128, 129 -&gt; #0
<BR>
[microtek] &gt; 0 80 0 81 0 0
<BR>
[microtek] read_from_scanner: gss busy, linewidth, remaining: 0, 128, 129
<BR>
[microtek] sane_read: max_scsi: 1024, rem: 129, nlines: 129
<BR>
[microtek] .read_scan_data...
<BR>
[microtek] sane_read: buffsize: 16512, unscanned: 0
<BR>
[microtek] pack_into_ring...
<BR>
[microtek] pack_into_dest...
<BR>
[microtek] pack_into_dest: rl: 16512 sz: 131072 hc: 0
<BR>
[microtek] sane_read...
<BR>
[microtek] end_scan...
<BR>
[microtek] .stop_scan...
<BR>
SPS:1b 0 0 0 0 0
<BR>
[microtek] SENSE! fd = 31
<BR>
[microtek] sense = 00 00 00 00.
<BR>
[microtek] sane_start...
<BR>
[microtek] sane_get_parameters...
<BR>
[microtek] sane_get_parameters: regular 3-pass color
<BR>
[microtek] sane_get_parameters: res_code = 5 ( 5)
<BR>
[microtek] sane_get_parameters: dots_per_mm: 3.937008
<BR>
[microtek] sane_get_parameters: units_per_mm: 71.968504
<BR>
[microtek] WIDTHPIX: before exp: 140
<BR>
[microtek] sane_get_parameters: lines: 141 ppl: 140 bpl: 140
<BR>
[microtek] set_pass_parameters: three-pass, on 2
<BR>
[microtek] sane_start: open of /dev/scanner failed: Invalid argument
<BR>
[microtek] end_scan...
<BR>
scanimage: sane_start: Invalid argument
<BR>
[microtek] sane_cancel...
<BR>
[microtek] end_scan...
<BR>
[microtek] sane_close...
<BR>
[microtek] sane_exit...
<BR>
[microtek] sane_exit: MICROTEK says goodbye.
<BR>
<P>No scanners were identified. If you were expecting something different,
<BR>
check that the scanner is plugged in, turned on and detected by the
<BR>
find-scanner tool (if appropriate). Please read the documentation which came
<BR>
with this software (README, FAQ, manpages).
<BR>
<P><P><PRE>
--
Source code, list archive, and docs: <A HREF="http://www.mostang.com/sane/">http://www.mostang.com/sane/</A>
To unsubscribe: echo unsubscribe sane-devel | mail <A HREF="mailto:majordomo@mostang.com?Subject=Re:%20Problem%20with%20Microtek%2035t%20slide/negative%20scanner&In-Reply-To=&lt;20010525082626.5265.qmail@web11501.mail.yahoo.com&gt;">majordomo@mostang.com</A>
</PRE>
<P><!-- body="end" -->
<HR NOSHADE>
<UL>
<!-- next="start" -->
<LI><STRONG>Next message:</STRONG> <A HREF="0337.html">Oliver Rauch: "Re: [BUG] Epson 1640SU, xsane preview problem]"</A>
<LI><STRONG>Previous message:</STRONG> <A HREF="0335.html">Oliver Rauch: "sane-net/saned problems solved?!"</A>
<!-- nextthread="start" -->
<LI><STRONG>Next in thread:</STRONG> <A HREF="0338.html">Jonathan Buzzard: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<LI><STRONG>Reply:</STRONG> <A HREF="0338.html">Jonathan Buzzard: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<LI><STRONG>Reply:</STRONG> <A HREF="0340.html">Matto Marjanovic: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<LI><STRONG>Reply:</STRONG> <A HREF="0371.html">EdHamrick@aol.com: "Re: Problem with Microtek 35t slide/negative scanner"</A>
<!-- reply="end" -->
<LI><STRONG>Messages sorted by:</STRONG>
<A HREF="date.html#336">[ date ]</A>
<A HREF="index.html#336">[ thread ]</A>
<A HREF="subject.html#336">[ subject ]</A>
<A HREF="author.html#336">[ author ]</A>
</UL>
<!-- trailer="footer" -->
<HR NOSHADE>
<P>
<SMALL>
<EM>
This archive was generated by <A HREF="http://www.hypermail.org/">hypermail 2b29</A>
: <EM>Fri May 25 2001 - 01:23:53 PDT</EM>
</EM>
</SMALL>
</BODY>
</HTML>