<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN"
|
|
"http://www.w3.org/TR/REC-html40/loose.dtd">
|
|
<HTML>
|
|
<HEAD>
|
|
<TITLE>sane-devel: Re: sane-umax-1.0.3-build-22 available</TITLE>
|
|
<META NAME="Author" CONTENT="Kymberly Tran (kymt@hotmail.com)">
|
|
<META NAME="Subject" CONTENT="Re: sane-umax-1.0.3-build-22 available">
|
|
</HEAD>
|
|
<BODY BGCOLOR="#FFFFFF" TEXT="#000000">
|
|
<H1>Re: sane-umax-1.0.3-build-22 available</H1>
|
|
<!-- received="Tue Aug 15 14:41:08 2000" -->
|
|
<!-- isoreceived="20000815214108" -->
|
|
<!-- sent="Tue, 15 Aug 2000 21:45:16 GMT" -->
|
|
<!-- isosent="20000815214516" -->
|
|
<!-- name="Kymberly Tran" -->
|
|
<!-- email="kymt@hotmail.com" -->
|
|
<!-- subject="Re: sane-umax-1.0.3-build-22 available" -->
|
|
<!-- id="F161VH96co9NOSvW81Z00000f26@hotmail.com" -->
|
|
<!-- inreplyto="sane-umax-1.0.3-build-22 available" -->
|
|
<STRONG>From:</STRONG> Kymberly Tran (<A HREF="mailto:kymt@hotmail.com?Subject=Re:%20sane-umax-1.0.3-build-22%20available&In-Reply-To=<F161VH96co9NOSvW81Z00000f26@hotmail.com>"><EM>kymt@hotmail.com</EM></A>)<BR>
|
|
<STRONG>Date:</STRONG> Tue Aug 15 2000 - 14:45:16 PDT
|
|
<P>
|
|
<!-- next="start" -->
|
|
<LI><STRONG>Next message:</STRONG> <A HREF="0139.html">Azarja Nieman: "Contact Image Sensor scanners"</A>
|
|
<UL>
|
|
<LI><STRONG>Previous message:</STRONG> <A HREF="0137.html">Paul Budden: "MicroTek 600ZS Problem"</A>
|
|
<LI><STRONG>Maybe in reply to:</STRONG> <A HREF="0107.html">Oliver Rauch: "sane-umax-1.0.3-build-22 available"</A>
|
|
<!-- nextthread="start" -->
|
|
<LI><STRONG>Next in thread:</STRONG> <A HREF="0140.html">Oliver Rauch: "Re: sane-umax-1.0.3-build-22 available"</A>
|
|
<LI><STRONG>Reply:</STRONG> <A HREF="0140.html">Oliver Rauch: "Re: sane-umax-1.0.3-build-22 available"</A>
|
|
<!-- reply="end" -->
|
|
<LI><STRONG>Messages sorted by:</STRONG>
|
|
<A HREF="date.html#138">[ date ]</A>
|
|
<A HREF="index.html#138">[ thread ]</A>
|
|
<A HREF="subject.html#138">[ subject ]</A>
|
|
<A HREF="author.html#138">[ author ]</A>
|
|
</UL>
|
|
<HR NOSHADE><P>
|
|
<!-- body="start" -->
|
|
<P>
|
|
Oliver,
|
|
<BR>
|
|
<P>When scanning the Kodak Gray Scale target, I've seen where its darker on top
|
|
<BR>
|
|
and lighter on the bottom of the gray scale target. I get inconsistent scan.
|
|
<BR>
|
|
Do you know if the lamp maintain it's brightness consistently for all scans?
|
|
<BR>
|
|
Does this build fix this problem?
|
|
<BR>
|
|
<P>Thanks,
|
|
<BR>
|
|
Kym
|
|
<BR>
|
|
<P><P><EM>>From: Oliver Rauch <<A HREF="mailto:oliver.rauch@Wolfsburg.DE?Subject=Re:%20sane-umax-1.0.3-build-22%20available&In-Reply-To=<F161VH96co9NOSvW81Z00000f26@hotmail.com>">oliver.rauch@Wolfsburg.DE</A>>
|
|
</EM><BR>
|
|
<EM>>Reply-To: <A HREF="mailto:sane-devel@mostang.com?Subject=Re:%20sane-umax-1.0.3-build-22%20available&In-Reply-To=<F161VH96co9NOSvW81Z00000f26@hotmail.com>">sane-devel@mostang.com</A>
|
|
</EM><BR>
|
|
<EM>>To: SANE-MAILLING-LIST <<A HREF="mailto:sane-devel@mostang.com?Subject=Re:%20sane-umax-1.0.3-build-22%20available&In-Reply-To=<F161VH96co9NOSvW81Z00000f26@hotmail.com>">sane-devel@mostang.com</A>>
|
|
</EM><BR>
|
|
<EM>>Subject: sane-umax-1.0.3-build-22 available
|
|
</EM><BR>
|
|
<EM>>Date: Sun, 13 Aug 2000 17:19:23 +0200
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>Hi,
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>sane-umax-1.0.3-build-22 is available on my homepage.
|
|
</EM><BR>
|
|
<EM>>The build-21 is included into sane-1.0.3.
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>I decided not to included build-22 into sane-1.0.3 because
|
|
</EM><BR>
|
|
<EM>>there was not enough time to test the scsi-command-queueing routines
|
|
</EM><BR>
|
|
<EM>>before sane-1.0.3-code-freeze has been defined.
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>On my system these routines work stable.
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>The lamp status routines are dfined for UMAX Astra 4000
|
|
</EM><BR>
|
|
<EM>>it looks like they do not work with Astra 2200/1220S/1200S
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>Here are the other news:
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * replaced fgets() by sanei_config_read()
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * added command queueing for scsi read commands
|
|
</EM><BR>
|
|
<EM>> - removed WAIT_SCANNER scsi command call after read command
|
|
</EM><BR>
|
|
<EM>> - the additional buffers are allocated in the reader process
|
|
</EM><BR>
|
|
<EM>> - the number of buffers can be defined in umax.conf
|
|
</EM><BR>
|
|
<EM>> with option scsi-maxqueue [1..8] default:2
|
|
</EM><BR>
|
|
<EM>> (did some tests with Supervista S12 and PowerLook III
|
|
</EM><BR>
|
|
<EM>> on the same scsi controller (ncr53c810):
|
|
</EM><BR>
|
|
<EM>> command queueing works, it is possible to start
|
|
</EM><BR>
|
|
<EM>> both scanners at the same time. The scanner with the
|
|
</EM><BR>
|
|
<EM>> higher scsi-ID (=priority) does scan without stops,
|
|
</EM><BR>
|
|
<EM>> the other scanner has to wait long time between the
|
|
</EM><BR>
|
|
<EM>> scsi-read commands, it also is possible to give
|
|
</EM><BR>
|
|
<EM>> bothe scanners different scsi command queueing depth).
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * prepared replacement of pipe by sanei_ipc_* routines
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * added routines umax_get_lamp_status and umax_set_lamp_status
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * updated inquiry output (new bits from powerlook scsi protocol 1.0
|
|
</EM><BR>
|
|
<EM>>X101)
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * added new (powerlook scsi protocol 1.0 X101) window descriptor block
|
|
</EM><BR>
|
|
<EM>>entries to umax-scsidef.h
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * added button protocol (3 buttons, from powerlook scsi protocol 1.0
|
|
</EM><BR>
|
|
<EM>>X101)
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * added button "lamp off" to turn off scanner lamp
|
|
</EM><BR>
|
|
<EM>> (this option may be remoeved again in later version, may be
|
|
</EM><BR>
|
|
<EM>> it will be replaced by an autmatic lamp turn off function)
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * added options to umax.conf
|
|
</EM><BR>
|
|
<EM>> lamp-off-at-exit [01] default:0
|
|
</EM><BR>
|
|
<EM>> lamp-off-time [10..720] (in minutes) default:30
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> * if lamp_off_at_exit == 1 and lamp_control_available == 1
|
|
</EM><BR>
|
|
<EM>> the scanner lamp is turned off in sane_close
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>> <A HREF="http://www.wolfsburg.de/~rauch/sane/sane-umax.html">http://www.wolfsburg.de/~rauch/sane/sane-umax.html</A>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>Bye
|
|
</EM><BR>
|
|
<EM>>Oliver
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>--
|
|
</EM><BR>
|
|
<EM>>E-Mail: mailto:<A HREF="mailto:Oliver.Rauch@Wolfsburg.DE?Subject=Re:%20sane-umax-1.0.3-build-22%20available&In-Reply-To=<F161VH96co9NOSvW81Z00000f26@hotmail.com>">Oliver.Rauch@Wolfsburg.DE</A>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>
|
|
</EM><BR>
|
|
<EM>>--
|
|
</EM><BR>
|
|
<EM>>Source code, list archive, and docs: <A HREF="http://www.mostang.com/sane/">http://www.mostang.com/sane/</A>
|
|
</EM><BR>
|
|
<EM>>To unsubscribe: echo unsubscribe sane-devel | mail <A HREF="mailto:majordomo@mostang.com?Subject=Re:%20sane-umax-1.0.3-build-22%20available&In-Reply-To=<F161VH96co9NOSvW81Z00000f26@hotmail.com>">majordomo@mostang.com</A>
|
|
</EM><BR>
|
|
<P>________________________________________________________________________
|
|
<BR>
|
|
Get Your Private, Free E-mail from MSN Hotmail at <A HREF="http://www.hotmail.com">http://www.hotmail.com</A>
|
|
<BR>
|
|
<P><P><PRE>
|
|
--
|
|
Source code, list archive, and docs: <A HREF="http://www.mostang.com/sane/">http://www.mostang.com/sane/</A>
|
|
To unsubscribe: echo unsubscribe sane-devel | mail <A HREF="mailto:majordomo@mostang.com?Subject=Re:%20sane-umax-1.0.3-build-22%20available&In-Reply-To=<F161VH96co9NOSvW81Z00000f26@hotmail.com>">majordomo@mostang.com</A>
|
|
</PRE>
|
|
<P><!-- body="end" -->
|
|
<HR NOSHADE>
|
|
<UL>
|
|
<!-- next="start" -->
|
|
<LI><STRONG>Next message:</STRONG> <A HREF="0139.html">Azarja Nieman: "Contact Image Sensor scanners"</A>
|
|
<LI><STRONG>Previous message:</STRONG> <A HREF="0137.html">Paul Budden: "MicroTek 600ZS Problem"</A>
|
|
<LI><STRONG>Maybe in reply to:</STRONG> <A HREF="0107.html">Oliver Rauch: "sane-umax-1.0.3-build-22 available"</A>
|
|
<!-- nextthread="start" -->
|
|
<LI><STRONG>Next in thread:</STRONG> <A HREF="0140.html">Oliver Rauch: "Re: sane-umax-1.0.3-build-22 available"</A>
|
|
<LI><STRONG>Reply:</STRONG> <A HREF="0140.html">Oliver Rauch: "Re: sane-umax-1.0.3-build-22 available"</A>
|
|
<!-- reply="end" -->
|
|
<LI><STRONG>Messages sorted by:</STRONG>
|
|
<A HREF="date.html#138">[ date ]</A>
|
|
<A HREF="index.html#138">[ thread ]</A>
|
|
<A HREF="subject.html#138">[ subject ]</A>
|
|
<A HREF="author.html#138">[ author ]</A>
|
|
</UL>
|
|
<!-- trailer="footer" -->
|
|
<HR NOSHADE>
|
|
<P>
|
|
<SMALL>
|
|
<EM>
|
|
This archive was generated by <A HREF="http://www.hypermail.org/">hypermail 2b29</A>
|
|
: <EM>Tue Aug 15 2000 - 14:46:01 PDT</EM>
|
|
</EM>
|
|
</SMALL>
|
|
</BODY>
|
|
</HTML>
|