<!-- received="Wed Apr 21 07:25:24 1999 PDT" -->
<!-- sent="Wed, 21 Apr 1999 07:24:48 -0700" -->
<!-- name="Brian Macy" -->
<!-- email="bmacy@sunshinecomputing.com" -->
<!-- subject="Anonymous CVS..." -->
<!-- id="" -->
<!-- inreplyto="" -->
<title>sane-devel: Anonymous CVS...</title>
<h1>Anonymous CVS...</h1>
<b>Brian Macy</b> (<a href="mailto:bmacy@sunshinecomputing.com"><i>bmacy@sunshinecomputing.com</i></a>)<br>
<i>Wed, 21 Apr 1999 07:24:48 -0700</i>
<p>
<ul>
<li> <b>Messages sorted by:</b> <a href="date.html#285">[ date ]</a><a href="index.html#285">[ thread ]</a><a href="subject.html#285">[ subject ]</a><a href="author.html#285">[ author ]</a>
<!-- next="start" -->
<li> <b>Next message:</b> <a href="0286.html">Oliver Rauch: "Re: 2 Channel SCSI Card"</a>
<li> <b>Previous message:</b> <a href="0284.html">David Mosberger-Tang: "SANE v1.0.1 released"</a>
<!-- nextthread="start" -->
<!-- reply="end" -->
</ul>
<!-- body="start" -->
I'd be curious how you secure CVS to provide anonymous access. I'd like to<br>
do so for WinSANE and other side projects of mine.<br>
<p>
Brian Macy<br>
<p>
----- Original Message -----<br>
From: David Mosberger-Tang &lt;<a href="mailto:David.Mosberger@acm.org">David.Mosberger@acm.org</a>&gt;<br>
To: &lt;<a href="mailto:sane-devel@mostang.com">sane-devel@mostang.com</a>&gt;<br>
Sent: Tuesday, April 20, 1999 10:31 PM<br>
Subject: SANE v1.0.1 released<br>
<p>
<p>
<i>&gt; All right, SANE v1.0.1 has finally been released. It can be found</i><br>
<i>&gt; at <a href="ftp://ftp.mostang.com/pub/sane/:">ftp://ftp.mostang.com/pub/sane/:</a></i><br>
<i>&gt;</i><br>
<i>&gt; -rw-r--r-- 1172 Apr 21 20:48 sane-1.0.1.lsm</i><br>
<i>&gt; -rw-r--r-- 996384 Apr 21 20:48 sane-1.0.1.tar.gz</i><br>
<i>&gt; -rw-r--r-- 199893 Apr 21 20:48 sane-1.00-1.0.1.diff.gz</i><br>
<i>&gt;</i><br>
<i>&gt; Hopefully, not too many bugs crept in this time (knock on wood...).</i><br>
<i>&gt;</i><br>
<i>&gt; Thanks to Ingo Wilken of the Computer Science department of the</i><br>
<i>&gt; University of Oldenburg, there is now an ftp mirror in Germany. To</i><br>
<i>&gt; reach it, simply go to ftp.de.mostang.com (instead of</i><br>
<i>&gt; ftp.mostang.com). Note that it may take a day or so until the mirror</i><br>
<i>&gt; is in sync with ftp.mostang.com. If others want to setup a similar</i><br>
<i>&gt; mirror for other countries, just send me the domain name. For this to</i><br>
<i>&gt; work reasonably, it should be possible to find SANE in directory</i><br>
<i>&gt; /pub/sane/ and the mirror should be updated at least once a day.</i><br>
<i>&gt;</i><br>
<i>&gt; A list of the most important changes since SANE v1.00 is appended</i><br>
<i>&gt; below. Thanks to everyone who contributed to this release!</i><br>
<i>&gt;</i><br>
<i>&gt; Enjoy,</i><br>
<i>&gt;</i><br>
<i>&gt; --david</i><br>
<i>&gt;</i><br>
<i>&gt; -*-Mode: outline-*-</i><br>
<i>&gt; New with 1.01:</i><br>
<i>&gt;</i><br>
<i>&gt; * Miscellaneous</i><br>
<i>&gt; o configure --disable-shared works again</i><br>
<i>&gt; o scanimage -T testing option added (by Nick Lamb)</i><br>
<i>&gt; o in dll.conf, the pnm, dc25, and dc210 backends are now disabled</i><br>
<i>&gt; (commented out) by default. The net backend is now enabled by</i><br>
<i>&gt; default. The pnm backend has been disabled as it often proved</i><br>
<i>&gt; confusing to novice users. The dc25 and dc210 backends were</i><br>
<i>&gt; disabled because they initialize very slowly if no camera is</i><br>
<i>&gt; attached.</i><br>
<i>&gt; o Downgraded PNM backend to the version shipped with SANE 0.74.</i><br>
<i>&gt; The scan area options as implemented in SANE 1.00 were</i><br>
<i>&gt; incorrectly implemented which made the backend unreliable.</i><br>
<i>&gt;</i><br>
<i>&gt; * New tool to turn off Mustek 600 II N scanner (by Andreas Czechanowski)</i><br>
<i>&gt; o the new binary tools/mustk600iin-off allows to turn off a</i><br>
<i>&gt; Mustek 600 II N scanner (note: you'll need to install this tool</i><br>
<i>&gt; manually if you want it)</i><br>
<i>&gt;</i><br>
<i>&gt; * New backend for Sharp scanners (by FUKUDA Kazuya &amp; Abel Deuring)</i><br>
<i>&gt; o supports the Sharp JX-610, JX-250, and JX-330 SCSI scanner</i><br>
<i>&gt; o preview/lineart/haftone/threshold are untested</i><br>
<i>&gt;</i><br>
<i>&gt; * Updated Kodak DC25 backend (by Peter Fales).</i><br>
<i>&gt;</i><br>
<i>&gt; * Updated HP backend (by Peter Kirchgessner)</i><br>
<i>&gt; o New features:</i><br>
<i>&gt; - Option 'unload after scan' for PhotoScanner</i><br>
<i>&gt; - Manual page sane-hp updated</i><br>
<i>&gt; - hp.desc updated</i><br>
<i>&gt;</i><br>
<i>&gt; o Bugfixes:</i><br>
<i>&gt; - Adjustable scan size for scan from ADF</i><br>
<i>&gt; - No blanks in command line options</i><br>
<i>&gt; - Segmentation fault for starting scanimage -d hp:/dev/sg0</i><br>
<i>&gt; without /dev/sgo in hp.conf</i><br>
<i>&gt;</i><br>
<i>&gt; Scanning from the ADF therefore should work now.</i><br>
<i>&gt;</i><br>
<i>&gt; * Updated Microtek backend (by Matto Marjanovic)</i><br>
<i>&gt; o Fixed off-by-1 error in revision-number parsing.</i><br>
<i>&gt; o dump_inquiry() now prints the "Vendor Specific String".</i><br>
<i>&gt; o Added model code/vendor name for the other 600ZS.</i><br>
<i>&gt; o Made get_scan_status() retry delay increase with each try (will</i><br>
<i>&gt; this help the poor 600ZS?).</i><br>
<i>&gt; o Corrected base resolution for Agfa StudioScan II/IIsi (400dpi).</i><br>
<i>&gt; o Disabled backend's clever aspect-ratio correction code for</i><br>
<i>&gt; expanded-mode scans with StudioScan II/IIsi (scanner handles it</i><br>
<i>&gt; internally - smart scanner.)</i><br>
<i>&gt; o Fixed gamma LUT code parsing stupidity: now correctly</i><br>
<i>&gt; determines maximum allowed LUT size, and uses it. (Especially</i><br>
<i>&gt; necessary for StudioScan II/IIsi.)</i><br>
<i>&gt; o The E6 claims to only support 256-byte LUT's, but the backend</i><br>
<i>&gt; now ignores that misinformation (and uses 1024).</i><br>
<i>&gt; o Now ignores denial of expanded-mode by older E6's (model code</i><br>
<i>&gt; 0x63), in addition to newer E6's.</i><br>
<i>&gt;</i><br>
<i>&gt; * Updated Microtek2 backend (by Bernd Schroeder)</i><br>
<i>&gt; o Added support for non-blocking I/O.</i><br>
<i>&gt; o Preliminary support for a strip and a slide mode.</i><br>
<i>&gt; o For people, who are annoyed, if the the scanhead moves back and</i><br>
fourth<br>
<i>&gt; during a scan (backtracking): There is a new option 'disable</i><br>
<i>&gt; backtracking'. At present this option must be activated by</i><br>
<i>&gt; uncommenting the respective entry in the included microtek2.conf</i><br>
<i>&gt; file. This is an advanced option.</i><br>
<i>&gt; o The X6EL should no longer produce pixel junk after one successful</i><br>
scan.<br>
<i>&gt;</i><br>
<i>&gt; * Updated Mustek backend (by Andreas Bolsch)</i><br>
<i>&gt; o larger buffer acquired (speeds up scanning slightly)</i><br>
<i>&gt; o for SE models minimal resolution increased from 60 dpi to 75 dpi</i><br>
<i>&gt; o for SE models 75 dpi in color mode is no longer used as the newer</i><br>
<i>&gt; firware version seems to be even more buggy</i><br>
<i>&gt; o bug in calculation of gamma table corrected (applies only to SE</i><br>
models,<br>
<i>&gt; NOT related to the overflow problem which was corrected via CLIP( ) )</i><br>
<i>&gt; o default resolution is now set according to the minimal resolution</i><br>
<i>&gt; (firmware dependent)</i><br>
<i>&gt; o for SE models all unsupported options (speed, ... ) explicitly</i><br>
disabled<br>
<i>&gt;</i><br>
<i>&gt; * Updated Nikon Coolscan backend (by Didier Carlier)</i><br>
<i>&gt; o Reverse the pixel order for the LS-1000.</i><br>
<i>&gt;</i><br>
<i>&gt; * Updated snapscan backend to v0.6 (by Kevin Charter and Petter</i><br>
Reinholdtsen)<br>
<i>&gt; o Fixes the versioning problem.</i><br>
<i>&gt; o Add support for SnapScan 1236s (should also work for SnapScan 600).</i><br>
<i>&gt;</i><br>
<i>&gt; * Updated UMAX backend (by Oliver Rauch)</i><br>
<i>&gt; o Added support for Linotype Hell Saphir 2</i><br>
<i>&gt; o Changed bug in gray gamma data conversion</i><br>
<i>&gt; o Added support for Nikon AX-210</i><br>
<i>&gt; o Added "Vista S-6E" as supported</i><br>
<i>&gt; o Added PowerLook-II (PL-II) as supported</i><br>
<i>&gt; o Added Astra 600S as supported</i><br>
<i>&gt;</i><br>
<i>&gt; --</i><br>
<i>&gt; Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a></i><br>
<i>&gt; To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a></i><br>
<i>&gt;</i><br>
<p>
<p>
<pre>
--
Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a>
To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a>
</pre>
<!-- body="end" -->
<p>
<ul>
<!-- next="start" -->
<li> <b>Next message:</b> <a href="0286.html">Oliver Rauch: "Re: 2 Channel SCSI Card"</a>
<li> <b>Previous message:</b> <a href="0284.html">David Mosberger-Tang: "SANE v1.0.1 released"</a>
<!-- nextthread="start" -->
<!-- reply="end" -->
</ul>