<!-- received="Fri Aug 14 19:53:29 1998 PDT" -->
|
||
<!-- sent="Fri, 14 Aug 1998 22:52:36 -0400 (EDT)" -->
|
||
<!-- name="Sreenivasa Sista" -->
|
||
<!-- email="ssista@ece.neu.edu" -->
|
||
<!-- subject="Re: SCSI-II scanner command list - specification file - common lib" -->
|
||
<!-- id="" -->
|
||
<!-- inreplyto="m0yyGK1-000J2XC@yoo-hoo.ai.mit.edu" -->
|
||
<title>sane-devel: Re: SCSI-II scanner command list - specification file - common lib</title>
|
||
<h1>Re: SCSI-II scanner command list - specification file - common lib</h1>
|
||
<b>Sreenivasa Sista</b> (<a href="mailto:ssista@ece.neu.edu"><i>ssista@ece.neu.edu</i></a>)<br>
|
||
<i>Fri, 14 Aug 1998 22:52:36 -0400 (EDT)</i>
|
||
<p>
|
||
<ul>
|
||
<li> <b>Messages sorted by:</b> <a href="date.html#74">[ date ]</a><a href="index.html#74">[ thread ]</a><a href="subject.html#74">[ subject ]</a><a href="author.html#74">[ author ]</a>
|
||
<!-- next="start" -->
|
||
<li> <b>Next message:</b> <a href="0075.html">Marc Pentenrieder: "Re: Problem with Mustek Scanexpress 12000 SP"</a>
|
||
<li> <b>Previous message:</b> <a href="0073.html">MIchael Katz-Hyman: "Info Peripherals Scanner"</a>
|
||
<!-- nextthread="start" -->
|
||
<!-- reply="end" -->
|
||
</ul>
|
||
<!-- body="start" -->
|
||
Hi Matt,<br>
|
||
<p>
|
||
I was very busy for last few weeks. Now I've got the Inquiry information <br>
|
||
for the LEO Scan S3. I hope the INQUIRY information makes some sense<br>
|
||
to the people who had put a lot of effort in building the backends<br>
|
||
for varioius scanners.<br>
|
||
<p>
|
||
If you need more information, please let me know.<br>
|
||
<p>
|
||
Sreenivasa Sista<br>
|
||
<p>
|
||
<p>
|
||
----------------------------------------------------------------------<br>
|
||
<p>
|
||
I've used the microtek backed on LEO. I changed everything named microtek<br>
|
||
to LEO. I've also made changes so that the control reaches the printing<br>
|
||
of INQUIRY information:<br>
|
||
<p>
|
||
-----------------------------------------------------------------------------------------<br>
|
||
<p>
|
||
/home/ssreeniv/tmp/sane-0.73/tools]#./find-scanner <br>
|
||
find-scanner: found scanner "LEO LEOScan-S3 3.01" at device /dev/scanner<br>
|
||
find-scanner: found scanner "LEO LEOScan-S3 3.01" at device /dev/sga<br>
|
||
<p>
|
||
------------------------------------------------------------------------------------------<br>
|
||
<p>
|
||
/home/ssreeniv/tmp]#scanimage <br>
|
||
[sanei_init_debug]: Setting debug level of dll to 128.<br>
|
||
[dll] adding backend LEO<br>
|
||
[dll] loading backend LEO<br>
|
||
[dll] dlopen()ing `/usr/local/lib/sane/libsane-LEO.so.0'<br>
|
||
[dll] init: initializing backend `LEO'<br>
|
||
[sanei_init_debug]: Setting debug level of LEO to 128.<br>
|
||
[LEO] sane_init: LEO says hello! (v0.7)<br>
|
||
[LEO] sane_init: config- scsi * * Scanner<br>
|
||
[LEO] attach_scanner: /dev/sga<br>
|
||
[LEO] attach_scanner: opening /dev/sga<br>
|
||
[LEO] attach_scanner: sending INQUIRY<br>
|
||
[LEO] id_LEO...<br>
|
||
[LEO] id_LEO: model_string val: 32<br>
|
||
[LEO] attach_scanner: device doesn't look like a LEO scanner.[LEO] dump_suspect_inquiry...<br>
|
||
=== SANE/LEO backend v0.7 ===<br>
|
||
========== Scanner Inquiry Block ========mm<br>
|
||
06 31 14 01 1f 00 00 00 4c 45 4f 20 20 20 20 20 <br>
|
||
4c 45 4f 53 63 61 6e 2d 53 33 20 20 20 20 20 20 <br>
|
||
33 2e 30 31 09 f6 0d b6 01 2c 01 2c 39 36 30 30 <br>
|
||
7f 31 14 01 1f 00 00 00 4c 45 4f 20 20 20 20 20 <br>
|
||
4c 45 4f 53 63 61 6e 2d 53 33 20 20 20 20 20 20 <br>
|
||
33 2e 30 31 09 f6 0d b6 01 2c 01 2c 39 36 30 30 <br>
|
||
<p>
|
||
========== Scanner Inquiry Report ==========<br>
|
||
===== Scanner ID...<br>
|
||
Device Type Code: 0x06<br>
|
||
Model Code: 0x20<br>
|
||
Vendor Name: 'LEO ' Model Name: 'LEOScan-S3 '<br>
|
||
Firmware Rev: '3.01<EFBFBD>'<br>
|
||
SCSI F/W version: 3.1 Scanner F/W version: 1.4<br>
|
||
Response data format: 0x01<br>
|
||
<p>
|
||
<p>
|
||
[LEO] attach_scanner: /dev/sga<br>
|
||
[LEO] attach_scanner: opening /dev/sga<br>
|
||
[LEO] attach_scanner: sending INQUIRY<br>
|
||
[LEO] id_LEO...<br>
|
||
[LEO] id_LEO: model_string val: 32<br>
|
||
[LEO] attach_scanner: device doesn't look like a LEO scanner.[LEO] dump_suspect_inquiry...<br>
|
||
=== SANE/LEO backend v0.7 ===<br>
|
||
========== Scanner Inquiry Block ========mm<br>
|
||
06 31 14 01 1f 00 00 00 4c 45 4f 20 20 20 20 20 <br>
|
||
4c 45 4f 53 63 61 6e 2d 53 33 20 20 20 20 20 20 <br>
|
||
33 2e 30 31 09 f6 0d b6 01 2c 01 2c 39 36 30 30 <br>
|
||
7f 31 14 01 1f 00 00 00 4c 45 4f 20 20 20 20 20 <br>
|
||
4c 45 4f 53 63 61 6e 2d 53 33 20 20 20 20 20 20 <br>
|
||
33 2e 30 31 09 f6 0d b6 01 2c 01 2c 39 36 30 30 <br>
|
||
<p>
|
||
========== Scanner Inquiry Report ==========<br>
|
||
===== Scanner ID...<br>
|
||
Device Type Code: 0x06<br>
|
||
Model Code: 0x20<br>
|
||
Vendor Name: 'LEO ' Model Name: 'LEOScan-S3 '<br>
|
||
Firmware Rev: '3.01'<br>
|
||
SCSI F/W version: 3.1 Scanner F/W version: 1.4<br>
|
||
Response data format: 0x01<br>
|
||
<p>
|
||
[LEO] sane_init: config- # See the man page for a description of the dump=n option<br>
|
||
[LEO] sane_init: config- #dump=1<br>
|
||
[LEO] sane_init: config- /dev/scanner<br>
|
||
[LEO] attach_scanner: /dev/scanner<br>
|
||
[LEO] attach_scanner: opening /dev/scanner<br>
|
||
[LEO] attach_scanner: sending INQUIRY<br>
|
||
[LEO] id_LEO...<br>
|
||
[LEO] id_LEO: model_string val: 32<br>
|
||
[LEO] attach_scanner: device doesn't look like a LEO scanner.[LEO] dump_suspect_inquiry...<br>
|
||
=== SANE/LEO backend v0.7 ===<br>
|
||
========== Scanner Inquiry Block ========mm<br>
|
||
06 31 14 01 1f 00 00 00 4c 45 4f 20 20 20 20 20 <br>
|
||
4c 45 4f 53 63 61 6e 2d 53 33 20 20 20 20 20 20 <br>
|
||
33 2e 30 31 09 f6 0d b6 01 2c 01 2c 39 36 30 30 <br>
|
||
7f 31 14 01 1f 00 00 00 4c 45 4f 20 20 20 20 20 <br>
|
||
4c 45 4f 53 63 61 6e 2d 53 33 20 20 20 20 20 20 <br>
|
||
33 2e 30 31 09 f6 0d b6 01 2c 01 2c 39 36 30 30 <br>
|
||
<p>
|
||
========== Scanner Inquiry Report ==========<br>
|
||
===== Scanner ID...<br>
|
||
Device Type Code: 0x06<br>
|
||
Model Code: 0x20<br>
|
||
Vendor Name: 'LEO ' Model Name: 'LEOScan-S3 '<br>
|
||
Firmware Rev: '3.01'<br>
|
||
SCSI F/W version: 3.1 Scanner F/W version: 1.4<br>
|
||
Response data format: 0x01<br>
|
||
<p>
|
||
<p>
|
||
[LEO] sane_get_devices<br>
|
||
scanimage: no SANE devices found<br>
|
||
[dll] exiting<br>
|
||
[dll] calling backend `LEO's exit function<br>
|
||
[LEO] sane_exit...<br>
|
||
[LEO] sane_exit: LEO says goodbye.<br>
|
||
<p>
|
||
-----------------------------------------------<br>
|
||
<p>
|
||
<p>
|
||
On Mon, 20 Jul 1998, Matto Marjanovic wrote:<br>
|
||
<p>
|
||
<i>> </i><br>
|
||
<i>> >From: <a href="mailto:charter@cs.ualberta.ca">charter@cs.ualberta.ca</a></i><br>
|
||
<i>> >Date: Sun, 19 Jul 1998 13:41:24 -0600 (MDT)</i><br>
|
||
<i>> </i><br>
|
||
<i>> >> I tried Umax, Microtek, Mustek and I have no clue of what the returned</i><br>
|
||
<i>> >> information means. I did not try Agfa-Snapscan-310, i'll try that one and</i><br>
|
||
<i>> >> see what happens.I tried contacting www.leoimage.com, who is the</i><br>
|
||
<i>> ></i><br>
|
||
<i>> >It probably won't work even if the scanner is SnapScan compatible,</i><br>
|
||
<i>> >because the backend examines the firmware vendor and model information</i><br>
|
||
<i>> >returned by an inquiry command and refuses to talk to scanners it</i><br>
|
||
<i>> >doesn't recognize. This is to protect people from damaging their</i><br>
|
||
<i>> </i><br>
|
||
<i>> Yep... which is why this compatibility discussion is all empty</i><br>
|
||
<i>> speculation until we see what the INQUIRY information actually says.</i><br>
|
||
<i>> </i><br>
|
||
<i>> -matt m.</i><br>
|
||
<i>> </i><br>
|
||
<i>> --</i><br>
|
||
<i>> Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a></i><br>
|
||
<i>> To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a></i><br>
|
||
<i>> </i><br>
|
||
<p>
|
||
<p>
|
||
<p>
|
||
<pre>
|
||
--
|
||
Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a>
|
||
To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a>
|
||
</pre>
|
||
<!-- body="end" -->
|
||
<p>
|
||
<ul>
|
||
<!-- next="start" -->
|
||
<li> <b>Next message:</b> <a href="0075.html">Marc Pentenrieder: "Re: Problem with Mustek Scanexpress 12000 SP"</a>
|
||
<li> <b>Previous message:</b> <a href="0073.html">MIchael Katz-Hyman: "Info Peripherals Scanner"</a>
|
||
<!-- nextthread="start" -->
|
||
<!-- reply="end" -->
|
||
</ul>
|