sane-project-website/old-archive/1998-04/0046.html

68 wiersze
3.2 KiB
HTML

<!-- received="Fri Apr 3 15:24:55 1998 PST" -->
<!-- sent="Sat, 4 Apr 1998 01:24:17 +0200 (MET DST)" -->
<!-- name="Hardy Pawletta " -->
<!-- email="pawletta@physik.rwth-aachen.de" -->
<!-- subject="Problem with Mustek Paragon 600 II SP" -->
<!-- id="Pine.OSF.3.94.980404012311.31679A-100000@acaxp6" -->
<!-- inreplyto="" -->
<title>sane-devel: Problem with Mustek Paragon 600 II SP</title>
<h1>Problem with Mustek Paragon 600 II SP</h1>
<b>Hardy Pawletta </b> (<a href="mailto:pawletta@physik.rwth-aachen.de"><i>pawletta@physik.rwth-aachen.de</i></a>)<br>
<i>Sat, 4 Apr 1998 01:24:17 +0200 (MET DST)</i>
<p>
<ul>
<li> <b>Messages sorted by:</b> <a href="date.html#46">[ date ]</a><a href="index.html#46">[ thread ]</a><a href="subject.html#46">[ subject ]</a><a href="author.html#46">[ author ]</a>
<!-- next="start" -->
<li> <b>Next message:</b> <a href="0047.html">David Mosberger-Tang: "Re: sane_read returning *len == 0"</a>
<li> <b>Previous message:</b> <a href="0045.html">Martin Radford: "Re: Mustek MSF-06000SP Rev. 2.10"</a>
<!-- nextthread="start" -->
<li> <b>Next in thread:</b> <a href="0048.html">Hugo van der Kooij: "Re: Problem with Mustek Paragon 600 II SP"</a>
<li> <b>Reply:</b> <a href="0048.html">Hugo van der Kooij: "Re: Problem with Mustek Paragon 600 II SP"</a>
<!-- reply="end" -->
</ul>
<!-- body="start" -->
Hi,<br>
<p>
I own a Mustek Paragon 600 II SP which is recognized as MFC-06000CZ with<br>
firmware rev. 2.03. The scanner is connected as the only device to a<br>
NCR810 based scsi controller.<br>
<p>
sane Version: 0.71 <br>
Generic scsi buffer is at maximum<br>
<p>
find-scanner reports:<br>
find-scanner: found scanner "SCANNER 2.03" at device /dev/scanner<br>
find-scanner: found scanner "SCANNER 2.03" at device /dev/sg0<br>
<p>
Gray scans and bw linart works but sometimes lines are lost. <br>
If I select Color scan option the scanner moves forward a bit then back<br>
again after that forward and backward and so on. The result seems to be ok<br>
but the scan needs a very long time (several minutes for 300dpi, full<br>
page) and the scanner didn't sound good. <br>
<p>
Did anybody know a sollution for this Problem ?<br>
<p>
------------------------------------------------------------<br>
Hardy Pawletta - III.Physics Institut B - RWTH-Aachen<br>
EMail: <a href="mailto:pawletta@physik.rwth-aachen.de">pawletta@physik.rwth-aachen.de</a><br>
------------------------------------------------------------<br>
<p>
<p>
<p>
<pre>
--
Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a>
To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a>
</pre>
<!-- body="end" -->
<p>
<ul>
<!-- next="start" -->
<li> <b>Next message:</b> <a href="0047.html">David Mosberger-Tang: "Re: sane_read returning *len == 0"</a>
<li> <b>Previous message:</b> <a href="0045.html">Martin Radford: "Re: Mustek MSF-06000SP Rev. 2.10"</a>
<!-- nextthread="start" -->
<li> <b>Next in thread:</b> <a href="0048.html">Hugo van der Kooij: "Re: Problem with Mustek Paragon 600 II SP"</a>
<li> <b>Reply:</b> <a href="0048.html">Hugo van der Kooij: "Re: Problem with Mustek Paragon 600 II SP"</a>
<!-- reply="end" -->
</ul>