<h1>Re: Probable Bugs &amp; Suggestions</h1>
<a href="mailto:becka@rz.uni-duesseldorf.de"><i>becka@rz.uni-duesseldorf.de</i></a><br>
<i>Fri, 19 Dec 1997 13:36:18 +0100 (MET)</i>
<p>
<ul>
<li> <b>Messages sorted by:</b> <a href="date.html#113">[ date ]</a><a href="index.html#113">[ thread ]</a><a href="subject.html#113">[ subject ]</a><a href="author.html#113">[ author ]</a>
<!-- next="start" -->
<li> <b>Next message:</b> <a href="0114.html">Lutz Stege: "xscanimage won't start"</a>
<li> <b>Previous message:</b> <a href="0112.html">Lutz Stege: "Re: How to turn off lamp in ScanJet IIcx"</a>
<!-- nextthread="start" -->
<!-- reply="end" -->
</ul>
<!-- body="start" -->
<i>&gt; The calibration would correct effect of a certain scanner printer combination.</i><br>
<i>&gt; However, it would be a general correction not only valid for a printed and</i><br>
<i>&gt; then rescanned image, which would indeed make not very much sense, but for any</i><br>
<i>&gt; image. </i><br>
<p>
No. This would assume the scanner has a gamma of 1.0.<br>
<p>
The "Right Thing to Do" (TM) would be :<br>
<p>
Get a printed reference color table. These are available from some photo <br>
companies like Kodak.<br>
<p>
Now scan this one. As the color values of the table are known, the <br>
response curves for the scanner can now be calculated.<br>
<p>
Now you have to compare the values with the monitor image and modify the<br>
response curve until they match (assuming there is only a normal gamma <br>
mismatch, there are simplified tests for that like the 50% value &lt;-&gt;<br>
black/100% comparision).<br>
<p>
To calibrate the printer, you now print and scan the result. As the scanner<br>
is already calibrated, you can now calculate the printer response.<br>
<p>
I.e. you need to calibrate each device individually. otherwise you only get <br>
a combined response which is only valid for the same "image path".<br>
<p>
CU,Andy<br>
<p>
<pre>
--
Andreas Beck | Email : &lt;<a href="mailto:becka@sunserver1.rz.uni-duesseldorf.de">becka@sunserver1.rz.uni-duesseldorf.de</a>&gt;
<p>
<pre>
--
Source code, list archive, and docs: <a href="http://www.mostang.com/sane/">http://www.mostang.com/sane/</a>
To unsubscribe: echo unsubscribe sane-devel | mail <a href="mailto:majordomo@mostang.com">majordomo@mostang.com</a>
</pre>
<!-- body="end" -->
<p>
<ul>
<!-- next="start" -->
<li> <b>Next message:</b> <a href="0114.html">Lutz Stege: "xscanimage won't start"</a>
<li> <b>Previous message:</b> <a href="0112.html">Lutz Stege: "Re: How to turn off lamp in ScanJet IIcx"</a>
<!-- nextthread="start" -->
<!-- reply="end" -->
</ul>