spelling fixes for gt68xx backend
rodzic
f4385e21c3
commit
cbbfcd1121
|
@ -124,7 +124,7 @@ static const SANE_Device **devlist = 0;
|
|||
static GT68xx_Device **new_dev = 0;
|
||||
/* Length of new_dev array */
|
||||
static SANE_Int new_dev_len = 0;
|
||||
/* Number of entries alloced for new_dev */
|
||||
/* Number of entries allocated for new_dev */
|
||||
static SANE_Int new_dev_alloced = 0;
|
||||
/* Is this computer little-endian ?*/
|
||||
SANE_Bool little_endian;
|
||||
|
@ -1527,7 +1527,7 @@ sane_open (SANE_String_Const devicename, SANE_Handle * handle)
|
|||
}
|
||||
|
||||
/* The firmware check is disabled by default because it may confuse
|
||||
some scanners: So the firmware is loaded everytime. */
|
||||
some scanners: So the firmware is loaded every time. */
|
||||
#if 0
|
||||
RIE (gt68xx_device_check_firmware (dev, &firmware_loaded));
|
||||
firmware_loaded = SANE_FALSE;
|
||||
|
@ -2030,7 +2030,7 @@ sane_start (SANE_Handle handle)
|
|||
} while ((i<5) && (document==SANE_FALSE));
|
||||
if(document==SANE_FALSE)
|
||||
{
|
||||
DBG (4, "sane_start: no doucment detected after %d s\n",i);
|
||||
DBG (4, "sane_start: no document detected after %d s\n",i);
|
||||
return SANE_STATUS_NO_DOCS;
|
||||
}
|
||||
}
|
||||
|
|
|
@ -5,7 +5,7 @@
|
|||
# Put the firmware file into "@DATADIR@/sane/gt68xx/".
|
||||
|
||||
# Manual configuration is necessary for some scanners. Please uncomment the
|
||||
# override line and optinally the vendor and product lines that apply to your
|
||||
# override line and optionally the vendor and product lines that apply to your
|
||||
# scanner. For some scanners it's also necessary to change the name of the
|
||||
# firmware file.
|
||||
|
||||
|
|
|
@ -103,7 +103,7 @@ gt6801_check_plustek_firmware (GT68xx_Device * dev, SANE_Bool * loaded)
|
|||
*loaded = SANE_FALSE;
|
||||
|
||||
/* Until I find out if testing for req[3] & 0x80 is save, load the firmware
|
||||
everytime */
|
||||
every time */
|
||||
*loaded = SANE_FALSE;
|
||||
|
||||
return SANE_STATUS_GOOD;
|
||||
|
|
|
@ -1015,7 +1015,7 @@ struct GT68xx_Afe_Values
|
|||
|
||||
/** Calculate average black and maximum white
|
||||
*
|
||||
* This function is used for CCD scanners. The black mark to the left ist used
|
||||
* This function is used for CCD scanners. The black mark to the left is used
|
||||
* for the calculation of average black. The remaining calibration strip
|
||||
* is used for searching the segment whose white average is the highest.
|
||||
*
|
||||
|
@ -2664,7 +2664,7 @@ gt68xx_read_calibration (GT68xx_Scanner * scanner)
|
|||
return SANE_STATUS_IO_ERROR;
|
||||
}
|
||||
|
||||
/* TODO we should check endiannes and word alignment in case of a home
|
||||
/* TODO we should check endianness and word alignment in case of a home
|
||||
* directory used trough different archs */
|
||||
|
||||
/* TODO check for errors */
|
||||
|
|
|
@ -356,7 +356,7 @@ static SANE_Status gt68xx_scanner_stop_scan (GT68xx_Scanner * scanner);
|
|||
* This function stores in memory calibration data created at calibration
|
||||
* time into file
|
||||
* @param scanner Scanner object.
|
||||
* @return SANE_STATUS_GOOD when succesfull
|
||||
* @return SANE_STATUS_GOOD when successful
|
||||
*/
|
||||
static SANE_Status gt68xx_write_calibration (GT68xx_Scanner * scanner);
|
||||
|
||||
|
@ -365,7 +365,7 @@ static SANE_Status gt68xx_write_calibration (GT68xx_Scanner * scanner);
|
|||
* This function sets in memory calibration data from data saved into file.
|
||||
*
|
||||
* @param scanner Scanner object.
|
||||
* @return SANE_STATUS_GOOD when succesfull
|
||||
* @return SANE_STATUS_GOOD when successful
|
||||
*/
|
||||
static SANE_Status gt68xx_read_calibration (GT68xx_Scanner * scanner);
|
||||
|
||||
|
|
|
@ -71,7 +71,7 @@
|
|||
#define LOBYTE(w) ((SANE_Byte)(w))
|
||||
|
||||
|
||||
/* return if an error occured while the function was called */
|
||||
/* return if an error occurred while the function was called */
|
||||
#ifdef MAX_DEBUG
|
||||
|
||||
# define RIE(function) \
|
||||
|
@ -219,7 +219,7 @@ struct GT68xx_Command_Set
|
|||
/*@{ */
|
||||
|
||||
SANE_Byte request_type; /**< Request type (should be 0x40, vendor spec) */
|
||||
SANE_Byte request; /**< Vendor spec resquest (0x01 or 0x04) */
|
||||
SANE_Byte request; /**< Vendor spec request (0x01 or 0x04) */
|
||||
SANE_Word memory_read_value; /**< Memory read - wValue */
|
||||
SANE_Word memory_write_value; /**< Memory write - wValue */
|
||||
SANE_Word send_cmd_value; /**< Send normal command - wValue */
|
||||
|
@ -504,7 +504,7 @@ struct GT68xx_Device
|
|||
SANE_Bool active;
|
||||
|
||||
/** Device missing to flag devices that are unplugged
|
||||
* after sane_init and befor sane_exit */
|
||||
* after sane_init and before sane_exit */
|
||||
SANE_Bool missing;
|
||||
|
||||
/** Scanner model data. */
|
||||
|
@ -588,7 +588,7 @@ struct GT68xx_Scan_Parameters
|
|||
SANE_Int ld_shift_b;
|
||||
SANE_Int ld_shift_double;
|
||||
SANE_Int double_column;
|
||||
SANE_Int pixel_x0; /**< x start postion */
|
||||
SANE_Int pixel_x0; /**< x start position */
|
||||
};
|
||||
|
||||
|
||||
|
@ -763,7 +763,7 @@ static SANE_Status gt68xx_device_deactivate (GT68xx_Device * dev);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*
|
||||
* @warning
|
||||
* @a size must be a multiple of 64 (at least with GT6816), otherwise the
|
||||
|
@ -782,7 +782,7 @@ gt68xx_device_memory_write (GT68xx_Device * dev, SANE_Word addr,
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*
|
||||
* @warning
|
||||
* @a size must be a multiple of 64 (at least with GT6816), otherwise the
|
||||
|
@ -800,7 +800,7 @@ gt68xx_device_memory_read (GT68xx_Device * dev, SANE_Word addr,
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_req (GT68xx_Device * dev, GT68xx_Packet cmd, GT68xx_Packet res);
|
||||
|
@ -813,7 +813,7 @@ gt68xx_device_req (GT68xx_Device * dev, GT68xx_Packet cmd, GT68xx_Packet res);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_small_req (GT68xx_Device * dev, GT68xx_Packet cmd,
|
||||
|
@ -829,7 +829,7 @@ gt68xx_device_small_req (GT68xx_Device * dev, GT68xx_Packet cmd,
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_check_firmware (GT68xx_Device * dev, SANE_Bool * loaded);
|
||||
|
@ -850,7 +850,7 @@ gt68xx_device_download_firmware (GT68xx_Device * dev,
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_get_power_status (GT68xx_Device * dev, SANE_Bool * power_ok);
|
||||
|
@ -865,7 +865,7 @@ gt68xx_device_get_power_status (GT68xx_Device * dev, SANE_Bool * power_ok);
|
|||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_UNSUPPORTED - the scanner does not support TA connection.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_get_ta_status (GT68xx_Device * dev, SANE_Bool * ta_attached);
|
||||
|
@ -878,7 +878,7 @@ gt68xx_device_get_ta_status (GT68xx_Device * dev, SANE_Bool * ta_attached);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
* - #SANE_STATUS_UNSUPPORTED - unsupported request was made (like attempt to
|
||||
* turn on the TA lamp on a scanner which does not support TA).
|
||||
*/
|
||||
|
@ -895,7 +895,7 @@ gt68xx_device_lamp_control (GT68xx_Device * dev, SANE_Bool fb_lamp,
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success; the status in @a *moving is valid.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_is_moving (GT68xx_Device * dev, SANE_Bool * moving);
|
||||
|
@ -912,7 +912,7 @@ gt68xx_device_is_moving (GT68xx_Device * dev, SANE_Bool * moving);
|
|||
* - #SANE_STATUS_GOOD - success; the movement is started. Call
|
||||
* gt68xx_device_is_moving() periodically to determine when the movement is
|
||||
* complete.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_move_relative (GT68xx_Device * dev, SANE_Int distance);
|
||||
|
@ -929,7 +929,7 @@ gt68xx_device_move_relative (GT68xx_Device * dev, SANE_Int distance);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success; the movement is started.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status gt68xx_device_carriage_home (GT68xx_Device * dev);
|
||||
|
||||
|
@ -940,7 +940,7 @@ static SANE_Status gt68xx_device_carriage_home (GT68xx_Device * dev);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success; the movement is started.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status gt68xx_device_paperfeed (GT68xx_Device * dev);
|
||||
|
||||
|
@ -958,7 +958,7 @@ static SANE_Status gt68xx_device_paperfeed (GT68xx_Device * dev);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status gt68xx_device_start_scan (GT68xx_Device * dev);
|
||||
|
||||
|
@ -977,7 +977,7 @@ static SANE_Status gt68xx_device_start_scan (GT68xx_Device * dev);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success; the value in @a *ready is valid.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_read_scanned_data (GT68xx_Device * dev, SANE_Bool * ready);
|
||||
|
@ -991,7 +991,7 @@ gt68xx_device_read_scanned_data (GT68xx_Device * dev, SANE_Bool * ready);
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status gt68xx_device_stop_scan (GT68xx_Device * dev);
|
||||
|
||||
|
@ -1014,7 +1014,7 @@ static SANE_Status gt68xx_device_stop_scan (GT68xx_Device * dev);
|
|||
* are not supported by hardware.
|
||||
* - #SANE_STATUS_INVAL - some of the parameters in @a request, or the @a
|
||||
* action code, are completely invalid.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_setup_scan (GT68xx_Device * dev,
|
||||
|
@ -1029,7 +1029,7 @@ gt68xx_device_setup_scan (GT68xx_Device * dev,
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_set_afe (GT68xx_Device * dev, GT68xx_AFE_Parameters * params);
|
||||
|
@ -1048,7 +1048,7 @@ gt68xx_device_set_exposure_time (GT68xx_Device * dev,
|
|||
*
|
||||
* @return
|
||||
* - #SANE_STATUS_GOOD - success.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occured.
|
||||
* - #SANE_STATUS_IO_ERROR - a communication error occurred.
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_device_read_raw (GT68xx_Device * dev, SANE_Byte * buffer,
|
||||
|
@ -1085,7 +1085,7 @@ gt68xx_device_get_id (GT68xx_Device * dev);
|
|||
/** Read the device descriptor of the scanner.
|
||||
*
|
||||
* This function should be called before closing the device to make sure
|
||||
* that the device descriptor is propperly stored in the scanner's memory.
|
||||
* that the device descriptor is properly stored in the scanner's memory.
|
||||
* If that's not done, the next try to get the config descriptor will
|
||||
* result in a corrupted descriptor.
|
||||
*
|
||||
|
|
|
@ -81,7 +81,7 @@ gt68xx_delay_buffer_init (GT68xx_Delay_Buffer * delay,
|
|||
DBG (3, "gt68xx_delay_buffer_init: no memory for delay block\n");
|
||||
return SANE_STATUS_NO_MEM;
|
||||
}
|
||||
/* make sure that we will see if one of the unitialized lines get displayed */
|
||||
/* make sure that we will see if one of the uninitialized lines get displayed */
|
||||
for (i = 0; i < bytes_per_line * line_count; i++)
|
||||
delay->mem_block[i] = i % 256;
|
||||
|
||||
|
|
|
@ -143,7 +143,7 @@ static SANE_Status gt68xx_line_reader_free (GT68xx_Line_Reader * reader);
|
|||
*
|
||||
* @return
|
||||
* - SANE_STATUS_GOOD - read completed successfully
|
||||
* - other error value - an error occured
|
||||
* - other error value - an error occurred
|
||||
*/
|
||||
static SANE_Status
|
||||
gt68xx_line_reader_read (GT68xx_Line_Reader * reader,
|
||||
|
|
|
@ -342,7 +342,7 @@ shm_channel_writer_init (Shm_Channel * shm_channel)
|
|||
* This function may block waiting for a free buffer (if the reader process
|
||||
* does not process the data fast enough).
|
||||
*
|
||||
* After successfull call to this function the writer process should fill the
|
||||
* After successful call to this function the writer process should fill the
|
||||
* buffer with the data and pass the buffer identifier from @a buffer_id_return
|
||||
* to shm_channel_writer_put_buffer() to give the buffer to the reader process.
|
||||
*
|
||||
|
@ -355,7 +355,7 @@ shm_channel_writer_init (Shm_Channel * shm_channel)
|
|||
* waiting for it); @a buffer_id_return and @a buffer_addr_return are filled
|
||||
* with valid values.
|
||||
* - SANE_STATUS_EOF - the reader process has closed its half of the channel.
|
||||
* - SANE_STATUS_IO_ERROR - an I/O error occured.
|
||||
* - SANE_STATUS_IO_ERROR - an I/O error occurred.
|
||||
*/
|
||||
SANE_Status
|
||||
shm_channel_writer_get_buffer (Shm_Channel * shm_channel,
|
||||
|
@ -399,7 +399,7 @@ shm_channel_writer_get_buffer (Shm_Channel * shm_channel,
|
|||
* @return
|
||||
* - SANE_STATUS_GOOD - the buffer was successfully queued.
|
||||
* - SANE_STATUS_IO_ERROR - the reader process has closed its half of the
|
||||
* channel, or another I/O error occured.
|
||||
* channel, or another I/O error occurred.
|
||||
*/
|
||||
SANE_Status
|
||||
shm_channel_writer_put_buffer (Shm_Channel * shm_channel,
|
||||
|
@ -573,7 +573,7 @@ shm_channel_reader_start (Shm_Channel * shm_channel)
|
|||
* Otherwise, @a *buffer_id_return, @a *buffer_addr_return and @a
|
||||
* *buffer_bytes return are filled with valid values.
|
||||
* - SANE_STATUS_EOF - the writer process has closed its half of the channel.
|
||||
* - SANE_STATUS_IO_ERROR - an I/O error occured.
|
||||
* - SANE_STATUS_IO_ERROR - an I/O error occurred.
|
||||
*/
|
||||
SANE_Status
|
||||
shm_channel_reader_get_buffer (Shm_Channel * shm_channel,
|
||||
|
@ -627,7 +627,7 @@ shm_channel_reader_get_buffer (Shm_Channel * shm_channel,
|
|||
* @return
|
||||
* - SANE_STATUS_GOOD - the buffer was successfully released.
|
||||
* - SANE_STATUS_IO_ERROR - the writer process has closed its half of the
|
||||
* channel, or an unexpected I/O error occured.
|
||||
* channel, or an unexpected I/O error occurred.
|
||||
*/
|
||||
SANE_Status
|
||||
shm_channel_reader_put_buffer (Shm_Channel * shm_channel, SANE_Int buffer_id)
|
||||
|
|
|
@ -473,6 +473,6 @@
|
|||
:interface "USB"
|
||||
:usbid "0x04a7" "0x0444"
|
||||
:status :good
|
||||
:comment "Works upto 1200 dpi and 12 bits/color."
|
||||
:comment "Works up to 1200 dpi and 12 bits/color."
|
||||
|
||||
; -----------------------------------------------------------------------------
|
||||
|
|
|
@ -80,7 +80,7 @@ V 1.0.73 (2005-08-19)
|
|||
V 1.0.72 (2005-08-18)
|
||||
|
||||
* Finally fixed the problem concerning scanning on *BSD. Scanning only worked
|
||||
once. After that, the scanner wasn't even detected anymore beacuse the config
|
||||
once. After that, the scanner wasn't even detected anymore because the config
|
||||
descriptor returned by the device was corrupted. This is a hardware bug. When
|
||||
filling the internal memory of the scanner completely, the config descriptor
|
||||
is overwritten. The work-around is to ask the scanner for the device
|
||||
|
@ -205,7 +205,7 @@ V 1.0-61 (2004-06-18)
|
|||
* Check for status of read_scanned_data every 10 ms. Avoids short stops before
|
||||
scan data comes in.
|
||||
* Added resolution limit for using backtracking.
|
||||
* Reduced deafult CCD backtracking to 0x10 lines.
|
||||
* Reduced default CCD backtracking to 0x10 lines.
|
||||
* CCD coarse calibration:
|
||||
* Check if calib has succeeded per color now (fewer loops).
|
||||
* Added loop detection now.
|
||||
|
@ -399,7 +399,7 @@ V 1.0-40 (2003-02-22)
|
|||
- Added indormation about Medion 4394.
|
||||
- Mention ma1509 backend.
|
||||
- Fix segfault when calling sane_open with an empty device name.
|
||||
- Explicitely initialize global variables to avoid segfaults when calling
|
||||
- Explicitly initialize global variables to avoid segfaults when calling
|
||||
sane_init/sane_exit more than once.
|
||||
|
||||
V 1.0-39 (2003-02-16)
|
||||
|
@ -416,7 +416,7 @@ V 1.0-38 (2003-02-05)
|
|||
- Increase the lowest black for CCD coarse calibration to avoid too much black.
|
||||
- Adjusted internal gamma correction to avoid getting 0 for high gamma values.
|
||||
- CCD scanners use color mode for coarse+quality cal now. This fixes the
|
||||
problem with extremly high gains and terrible quality cal in gray mode at
|
||||
problem with extremely high gains and terrible quality cal in gray mode at
|
||||
least for the BearPaw 1200 TA.
|
||||
--> Thanks to Alexei V. Mezin for reporting these bugs.
|
||||
- Preview isn't always in 8 bit mode now (can be selected by option).
|
||||
|
@ -533,8 +533,8 @@ V 1.0-26 (2002-10-22)
|
|||
|
||||
- Several fixes for Medion MD-9385 and Artec Ultima 2000 based scanners. The
|
||||
Cytron MD 9385 works now.
|
||||
- Diabled Plustek-like firmware check again, didn't work for MD 9385.
|
||||
- Splitted flags for mirror_x and sset_home.
|
||||
- Disabled Plustek-like firmware check again, didn't work for MD 9385.
|
||||
- Split flags for mirror_x and sset_home.
|
||||
|
||||
V 1.0-25 (2002-10-20)
|
||||
|
||||
|
@ -575,7 +575,7 @@ V 1.0-22 (2002-10-07),
|
|||
- Line calibration uses the bit depth of the main scan now.
|
||||
- Vendor, product ids and other information is printed when debugging is active
|
||||
- Fixed segfault in attach ().
|
||||
- Fixed endianess issues (untested).
|
||||
- Fixed endianness issues (untested).
|
||||
- Code cleanup.
|
||||
|
||||
V 1.0-21 (2002-10-07),
|
||||
|
@ -612,7 +612,7 @@ V 1.0-18 (2002-10-01)
|
|||
|
||||
- Added detection of Artec Ultima 2000.
|
||||
- Updated Lexmark X70 settings.
|
||||
- Fixed segfault that occured when no device was detected.
|
||||
- Fixed segfault that occurred when no device was detected.
|
||||
- Changed test for loaded firmware for GT-6801 scanners.
|
||||
|
||||
V 1.0-17 (2002-10-01)
|
||||
|
@ -699,7 +699,7 @@ V 1.0-9 (2002-09-17)
|
|||
|
||||
- Added option to disable automatic gain (->less ugly colors for GT-6801
|
||||
based models)
|
||||
- Fixed segfault that occured when a scan was cancelled
|
||||
- Fixed segfault that occurred when a scan was cancelled
|
||||
- Preview uses slow but safe (?) 300 dpi 8 bit modes now
|
||||
- Fixed bug concerning X0/Y0 coordinates
|
||||
- Started implementing dpeth option (doesn't work yet)
|
||||
|
|
|
@ -33,7 +33,7 @@ Mustek BearPaw 2448 TA Plus:
|
|||
- Sometimes there is a USB protocol error when cancelling the scan?
|
||||
- top borders move with resolution (happened in the early days with 2400 TA!)
|
||||
- gray scans have different brightness
|
||||
- scan motor is bumpy and freezes sometimes, looks like accelaration is too big
|
||||
- scan motor is bumpy and freezes sometimes, looks like acceleration is too big
|
||||
(firmware problem?)
|
||||
- vertical stripes
|
||||
- TA settings are wrong
|
||||
|
@ -93,7 +93,7 @@ Mustek ScanExpress 1248 UB
|
|||
ok
|
||||
|
||||
Plustek OpticSlim 2400
|
||||
- only upto 1200 dpi vertical works
|
||||
- only up to 1200 dpi vertical works
|
||||
- only 8 and 12 bit work, 16 doesn't (check Windows)
|
||||
- exposure is extremely high and seems to have similar problems as with other
|
||||
CIS scanners (reaches limit also)
|
||||
|
@ -102,4 +102,4 @@ Mustek ScanExpress 2400 USB
|
|||
- make it work (nobody seems to have this device)
|
||||
|
||||
Visioneer OneTouch 7300
|
||||
- 16 bit doesn't seem to work despite beeing advertized
|
||||
- 16 bit doesn't seem to work despite being advertized
|
||||
|
|