kiln-controller-max31856/config.py.EXAMPLE

146 wiersze
5.4 KiB
Plaintext

import logging
from lib.max31856 import MAX31856
########################################################################
#
# General options
### Logging
log_level = logging.INFO
log_format = '%(asctime)s %(levelname)s %(name)s: %(message)s'
### Server
listening_ip = "0.0.0.0"
listening_port = 8081
### Cost Estimate
kwh_rate = 0.1319 # Rate in currency_type to calculate cost to run job
currency_type = "$" # Currency Symbol to show when calculating cost to run job
########################################################################
#
# GPIO Setup (BCM SoC Numbering Schema)
#
# Check the RasPi docs to see where these GPIOs are
# connected on the P1 header for your board type/rev.
# These were tested on a Pi B Rev2 but of course you
# can use whichever GPIO you prefer/have available.
### Outputs
gpio_heat = 23 # Switches zero-cross solid-state-relay
### Thermocouple Adapter selection:
# max31855 - bitbang SPI interface
# max31856 - bitbang SPI interface. must specify thermocouple_type.
max31855 = 1
max31856 = 0
# see lib/max31856.py for other thermocouple_type, only applies to max31856
thermocouple_type = MAX31856.MAX31856_S_TYPE
### Thermocouple Connection (using bitbang interfaces)
gpio_sensor_cs = 27
gpio_sensor_clock = 22
gpio_sensor_data = 17
gpio_sensor_di = 10 # only used with max31856
########################################################################
#
# duty cycle of the entire system in seconds
#
# Every N seconds a decision is made about switching the relay[s]
# on & off and for how long. The thermocouple is read
# temperature_average_samples times during and the average value is used.
sensor_time_wait = 2
########################################################################
#
# PID parameters
#
# These parameters control kiln temperature change. These settings work
# well with the simulated oven. You must tune them to work well with
# your specific kiln. Note that the integral pid_ki is
# inverted so that a smaller number means more integral action.
# from experimentation
#pid_kp = 10 # Proportional
#pid_ki = 50 # Integral
#pid_kd = 100 # Derivative
# from ZN tuning
pid_kp = 3.0662264423638184
pid_ki = 61.295706065671204
pid_kd = 144.07164331295013
########################################################################
#
# Initial heating and Integral Windup
#
# During initial heating, if the temperature is constantly under the
# setpoint,large amounts of Integral can accumulate. This accumulation
# causes the kiln to run above the setpoint for potentially a long
# period of time. These settings allow integral accumulation only when
# the temperature is close to the setpoint. This applies only to the integral.
stop_integral_windup = True
########################################################################
#
# Simulation parameters
simulate = False
sim_t_env = 60.0 # deg C
sim_c_heat = 100.0 # J/K heat capacity of heat element
sim_c_oven = 5000.0 # J/K heat capacity of oven
sim_p_heat = 5450.0 # W heating power of oven
sim_R_o_nocool = 1.0 # K/W thermal resistance oven -> environment
sim_R_o_cool = 0.05 # K/W " with cooling
sim_R_ho_noair = 0.1 # K/W thermal resistance heat element -> oven
sim_R_ho_air = 0.05 # K/W " with internal air circulation
########################################################################
#
# Time and Temperature parameters
#
# If you change the temp_scale, all settings in this file are assumed to
# be in that scale.
temp_scale = "f" # c = Celsius | f = Fahrenheit - Unit to display
time_scale_slope = "h" # s = Seconds | m = Minutes | h = Hours - Slope displayed in temp_scale per time_scale_slope
time_scale_profile = "m" # s = Seconds | m = Minutes | h = Hours - Enter and view target time in time_scale_profile
# emergency shutoff the profile if this temp is reached or exceeded.
# This just shuts off the profile. If your SSR is working, your kiln will
# naturally cool off. If your SSR has failed/shorted/closed circuit, this
# means your kiln receives full power until your house burns down.
# this should not replace you watching your kiln or use of a kiln-sitter
emergency_shutoff_temp = 2264 #cone 7
# If the kiln cannot heat or cool fast enough and is off by more than
# kiln_must_catch_up_max_error the entire schedule is shifted until
# the desired temperature is reached. If your kiln cannot attain the
# wanted temperature, the schedule will run forever. This is often used
# for heating as fast as possible in a section of a kiln schedule/profile.
kiln_must_catch_up = True
kiln_must_catch_up_max_error = 10 #degrees
# thermocouple offset
# If you put your thermocouple in ice water and it reads 36F, you can
# set set this offset to -4 to compensate. This probably means you have a
# cheap thermocouple. Invest in a better thermocouple.
thermocouple_offset=0
# some kilns/thermocouples start erroneously reporting "short"
# errors at higher temperatures due to plasma forming in the kiln.
# Set this to False to ignore these errors and assume the temperature
# reading was correct anyway
honour_theromocouple_short_errors = False
# number of samples of temperature to average.
# If you suffer from the high temperature kiln issue and have set
# honour_theromocouple_short_errors to False,
# you will likely need to increase this (eg I use 40)
temperature_average_samples = 40
# Thermocouple AC frequency filtering - set to True if in a 50Hz locale, else leave at False for 60Hz locale
ac_freq_50hz = False