menu "Example Connection Configuration"
orsource "$IDF_PATH/examples/common_components/env_caps/$IDF_TARGET/Kconfig.env_caps"
config EXAMPLE_CONNECT_WIFI
bool "connect using WiFi interface"
depends on !IDF_TARGET_LINUX && SOC_WIFI_SUPPORTED
default y
help
Protocol examples can use Wi-Fi and/or Ethernet to connect to the network.
Choose this option to connect with WiFi
if EXAMPLE_CONNECT_WIFI
config EXAMPLE_WIFI_SSID_PWD_FROM_STDIN
bool "Get ssid and password from stdin"
default n
help
Give the WiFi SSID and password from stdin.
config EXAMPLE_PROVIDE_WIFI_CONSOLE_CMD
depends on !EXAMPLE_WIFI_SSID_PWD_FROM_STDIN
bool "Provide wifi connect commands"
default y
help
Provide wifi connect commands for esp_console.
Please use `example_register_wifi_connect_commands` to register them.
config EXAMPLE_WIFI_SSID
depends on !EXAMPLE_WIFI_SSID_PWD_FROM_STDIN
string "WiFi SSID"
default "myssid"
help
SSID (network name) for the example to connect to.
config EXAMPLE_WIFI_PASSWORD
depends on !EXAMPLE_WIFI_SSID_PWD_FROM_STDIN
string "WiFi Password"
default "mypassword"
help
WiFi password (WPA or WPA2) for the example to use.
Can be left blank if the network has no security set.
config EXAMPLE_WIFI_CONN_MAX_RETRY
int "Maximum retry"
default 6
help
Set the Maximum retry to avoid station reconnecting to the AP unlimited,
in case the AP is really inexistent.
choice EXAMPLE_WIFI_SCAN_METHOD
prompt "WiFi Scan Method"
default EXAMPLE_WIFI_SCAN_METHOD_ALL_CHANNEL
help
WiFi scan method:
If "Fast" is selected, scan will end after find SSID match AP.
If "All Channel" is selected, scan will end after scan all the channel.
config EXAMPLE_WIFI_SCAN_METHOD_FAST
bool "Fast"
config EXAMPLE_WIFI_SCAN_METHOD_ALL_CHANNEL
bool "All Channel"
endchoice
menu "WiFi Scan threshold"
config EXAMPLE_WIFI_SCAN_RSSI_THRESHOLD
int "WiFi minimum rssi"
range -127 0
default -127
help
The minimum rssi to accept in the scan mode.
choice EXAMPLE_WIFI_SCAN_AUTH_MODE_THRESHOLD
prompt "WiFi Scan auth mode threshold"
default EXAMPLE_WIFI_AUTH_OPEN
help
The weakest authmode to accept in the scan mode.
config EXAMPLE_WIFI_AUTH_OPEN
bool "OPEN"
config EXAMPLE_WIFI_AUTH_WEP
bool "WEP"
config EXAMPLE_WIFI_AUTH_WPA_PSK
bool "WPA PSK"
config EXAMPLE_WIFI_AUTH_WPA2_PSK
bool "WPA2 PSK"
config EXAMPLE_WIFI_AUTH_WPA_WPA2_PSK
bool "WPA WPA2 PSK"
config EXAMPLE_WIFI_AUTH_WPA2_ENTERPRISE
bool "WPA2 ENTERPRISE"
config EXAMPLE_WIFI_AUTH_WPA3_PSK
bool "WPA3 PSK"
config EXAMPLE_WIFI_AUTH_WPA2_WPA3_PSK
bool "WPA2 WPA3 PSK"
config EXAMPLE_WIFI_AUTH_WAPI_PSK
bool "WAPI PSK"
endchoice
endmenu
choice EXAMPLE_WIFI_CONNECT_AP_SORT_METHOD
prompt "WiFi Connect AP Sort Method"
default EXAMPLE_WIFI_CONNECT_AP_BY_SIGNAL
help
WiFi connect AP sort method:
If "Signal" is selected, Sort matched APs in scan list by RSSI.
If "Security" is selected, Sort matched APs in scan list by security mode.
config EXAMPLE_WIFI_CONNECT_AP_BY_SIGNAL
bool "Signal"
config EXAMPLE_WIFI_CONNECT_AP_BY_SECURITY
bool "Security"
endchoice
endif
config EXAMPLE_CONNECT_ETHERNET
bool "connect using Ethernet interface"
depends on !IDF_TARGET_LINUX
default y if !SOC_WIFI_SUPPORTED
help
Protocol examples can use Wi-Fi and/or Ethernet to connect to the network.
Choose this option to connect with Ethernet
if EXAMPLE_CONNECT_ETHERNET
config EXAMPLE_ETHERNET_EMAC_TASK_STACK_SIZE
int "emac_rx task stack size"
default 2048
help
This set stack size for emac_rx task
config EXAMPLE_USE_SPI_ETHERNET
bool
choice EXAMPLE_ETHERNET_TYPE
prompt "Ethernet Type"
default EXAMPLE_USE_INTERNAL_ETHERNET if SOC_EMAC_SUPPORTED
default EXAMPLE_USE_W5500
help
Select which kind of Ethernet will be used in the example.
config EXAMPLE_USE_INTERNAL_ETHERNET
depends on SOC_EMAC_SUPPORTED
select ETH_USE_ESP32_EMAC
bool "Internal EMAC"
help
Select internal Ethernet MAC controller.
config EXAMPLE_USE_DM9051
bool "DM9051 Module"
select EXAMPLE_USE_SPI_ETHERNET
select ETH_USE_SPI_ETHERNET
select ETH_SPI_ETHERNET_DM9051
help
Select external SPI-Ethernet module.
config EXAMPLE_USE_W5500
bool "W5500 Module"
select EXAMPLE_USE_SPI_ETHERNET
select ETH_USE_SPI_ETHERNET
select ETH_SPI_ETHERNET_W5500
help
Select external SPI-Ethernet module (W5500).
config EXAMPLE_USE_OPENETH
bool "OpenCores Ethernet MAC (EXPERIMENTAL)"
select ETH_USE_OPENETH
help
When this option is enabled, the example is built with support for
OpenCores Ethernet MAC, which allows testing the example in QEMU.
Note that this option is used for internal testing purposes, and
not officially supported. Examples built with this option enabled
will not run on a real ESP32 chip.
endchoice # EXAMPLE_ETHERNET_TYPE
if EXAMPLE_USE_INTERNAL_ETHERNET
choice EXAMPLE_ETH_PHY_MODEL
prompt "Ethernet PHY Device"
default EXAMPLE_ETH_PHY_IP101
help
Select the Ethernet PHY device to use in the example.
config EXAMPLE_ETH_PHY_IP101
bool "IP101"
help
IP101 is a single port 10/100 MII/RMII/TP/Fiber Fast Ethernet Transceiver.
Goto http://www.icplus.com.tw/pp-IP101G.html for more information about it.
config EXAMPLE_ETH_PHY_RTL8201
bool "RTL8201/SR8201"
help
RTL8201F/SR8201F is a single port 10/100Mb Ethernet Transceiver with auto MDIX.
Goto http://www.corechip-sz.com/productsview.asp?id=22 for more information about it.
config EXAMPLE_ETH_PHY_LAN87XX
bool "LAN87xx"
help
Below chips are supported:
LAN8710A is a small footprint MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and
flexPWR® Technology.
LAN8720A is a small footprint RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support.
LAN8740A/LAN8741A is a small footprint MII/RMII 10/100 Energy Efficient Ethernet Transceiver
with HP Auto-MDIX and flexPWR® Technology.
LAN8742A is a small footprint RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and
flexPWR® Technology.
Goto https://www.microchip.com for more information about them.
config EXAMPLE_ETH_PHY_DP83848
bool "DP83848"
help
DP83848 is a single port 10/100Mb/s Ethernet Physical Layer Transceiver.
Goto http://www.ti.com/product/DP83848J for more information about it.
config EXAMPLE_ETH_PHY_KSZ80XX
bool "KSZ80xx"
help
With the KSZ80xx series, Microchip offers single-chip 10BASE-T/100BASE-TX
Ethernet Physical Layer Tranceivers (PHY).
The following chips are supported: KSZ8001, KSZ8021, KSZ8031, KSZ8041,
KSZ8051, KSZ8061, KSZ8081, KSZ8091
Goto https://www.microchip.com for more information about them.
endchoice
config EXAMPLE_ETH_MDC_GPIO
int "SMI MDC GPIO number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 23 if IDF_TARGET_ESP32
default 31 if IDF_TARGET_ESP32P4
help
Set the GPIO number used by SMI MDC.
config EXAMPLE_ETH_MDIO_GPIO
int "SMI MDIO GPIO number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 18 if IDF_TARGET_ESP32
default 27 if IDF_TARGET_ESP32P4
help
Set the GPIO number used by SMI MDIO.
endif
if EXAMPLE_USE_SPI_ETHERNET
config EXAMPLE_ETH_SPI_HOST
int "SPI Host Number"
range 0 2
default 1
help
Set the SPI host used to communicate with the SPI Ethernet Controller.
config EXAMPLE_ETH_SPI_SCLK_GPIO
int "SPI SCLK GPIO number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 14
help
Set the GPIO number used by SPI SCLK.
config EXAMPLE_ETH_SPI_MOSI_GPIO
int "SPI MOSI GPIO number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 13
help
Set the GPIO number used by SPI MOSI.
config EXAMPLE_ETH_SPI_MISO_GPIO
int "SPI MISO GPIO number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_IN_RANGE_MAX
default 12
help
Set the GPIO number used by SPI MISO.
config EXAMPLE_ETH_SPI_CS_GPIO
int "SPI CS GPIO number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 15
help
Set the GPIO number used by SPI CS.
config EXAMPLE_ETH_SPI_CLOCK_MHZ
int "SPI clock speed (MHz)"
range 5 80
default 36
help
Set the clock speed (MHz) of SPI interface.
config EXAMPLE_ETH_SPI_INT_GPIO
int "Interrupt GPIO number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_IN_RANGE_MAX
default 4
help
Set the GPIO number used by the SPI Ethernet module interrupt line.
endif # EXAMPLE_USE_SPI_ETHERNET
config EXAMPLE_ETH_PHY_RST_GPIO
int "PHY Reset GPIO number"
range -1 ENV_GPIO_OUT_RANGE_MAX
default 26 if IDF_TARGET_ESP32P4
default 5
help
Set the GPIO number used to reset PHY chip.
Set to -1 to disable PHY chip hardware reset.
config EXAMPLE_ETH_PHY_ADDR
int "PHY Address"
range 0 31 if EXAMPLE_USE_INTERNAL_ETHERNET
default 1
help
Set PHY address according your board schematic.
endif # EXAMPLE_CONNECT_ETHERNET
config EXAMPLE_CONNECT_PPP
bool "connect using Point to Point interface"
select LWIP_PPP_SUPPORT
help
Protocol examples can use PPP connection over serial line.
Choose this option to connect to the ppp server running
on your laptop over a serial line (either UART or USB ACM)
if EXAMPLE_CONNECT_PPP
choice EXAMPLE_CONNECT_PPP_DEVICE
prompt "Choose PPP device"
default EXAMPLE_CONNECT_PPP_DEVICE_USB
help
Select which peripheral to use to connect to the PPP server.
config EXAMPLE_CONNECT_PPP_DEVICE_USB
bool "USB"
depends on SOC_USB_OTG_SUPPORTED
select TINYUSB_CDC_ENABLED
help
Use USB ACM device.
config EXAMPLE_CONNECT_PPP_DEVICE_UART
bool "UART"
help
Use UART.
endchoice
menu "UART Configuration"
depends on EXAMPLE_CONNECT_PPP_DEVICE_UART
config EXAMPLE_CONNECT_UART_TX_PIN
int "TXD Pin Number"
default 4
range 0 31
help
Pin number of UART TX.
config EXAMPLE_CONNECT_UART_RX_PIN
int "RXD Pin Number"
default 5
range 0 31
help
Pin number of UART RX.
config EXAMPLE_CONNECT_UART_BAUDRATE
int "UART Baudrate"
default 115200
range 9600 3000000
help
Baudrate of the UART device
endmenu
config EXAMPLE_PPP_CONN_MAX_RETRY
int "Maximum retry"
default 6
help
Set the Maximum retry to avoid station reconnecting if the pppd
is not available
endif # EXAMPLE_CONNECT_PPP
config EXAMPLE_CONNECT_IPV4
bool
depends on LWIP_IPV4
default y
config EXAMPLE_CONNECT_IPV6
depends on EXAMPLE_CONNECT_WIFI || EXAMPLE_CONNECT_ETHERNET || EXAMPLE_CONNECT_PPP
bool "Obtain IPv6 address"
default y
select LWIP_IPV6
select LWIP_PPP_ENABLE_IPV6 if EXAMPLE_CONNECT_PPP
help
By default, examples will wait until any IP preferred (usually global) address is obtained,
allowing flexible deployment to IPv4-only, IPv6-only, or dual-stack networks.
Enables SLAAC (State-Less Address Auto-Configuration) to get IPv6
address prefixes from Router Advertisement (RA) messages, and both
RA RDNSS (Recursive DNS Server) and DHCPv6 Stateless mode to get IPv6 DNS
server details from whichever is available on the network.
if EXAMPLE_CONNECT_IPV6
config EXAMPLE_CONNECT_PREF_ANY
bool "Obtain any preferred address"
default y
help
By default, examples will wait until any IP preferred address is obtained, either an IPv4 or
IPv6 global scope addresses.
This enables flexible deployment into any network type.
Disable this option to wait for both address types, although this will break single-stack networks.
Choose the preferred IPv6 address type if the connection code should wait until other than
an IPv6 global address.
choice EXAMPLE_CONNECT_PREFERRED_IPV6
prompt "Preferred IPv6 Type"
default EXAMPLE_CONNECT_IPV6_PREF_GLOBAL
help
Select which kind of IPv6 address the connect logic waits for.
config EXAMPLE_CONNECT_IPV6_PREF_LOCAL_LINK
bool "Local Link Address"
help
Blocks until Local link address assigned.
config EXAMPLE_CONNECT_IPV6_PREF_GLOBAL
bool "Global Address"
help
Blocks until Global address assigned.
config EXAMPLE_CONNECT_IPV6_PREF_SITE_LOCAL
bool "Site Local Address"
help
Blocks until Site link address assigned.
config EXAMPLE_CONNECT_IPV6_PREF_UNIQUE_LOCAL
bool "Unique Local Link Address"
help
Blocks until Unique local address assigned.
endchoice
endif