* rtu_serial_io.c
|
|
*
|
|
* Created on: 27.08.2020
|
|
* Author: mateusz
|
|
*/
|
|
|
|
#include "modbus_rtu/rtu_configuration.h"
|
|
#include "modbus_rtu/rtu_serial_io.h"
|
|
#include "modbus_rtu/rtu_crc.h"
|
|
#include "modbus_rtu/rtu_parser.h"
|
|
#include "modbus_rtu/rtu_return_values.h"
|
|
#include "modbus_rtu/rtu_register_data_t.h"
|
|
#include "modbus_rtu/rtu_request.h"
|
|
|
|
#include "drivers/serial.h"
|
|
|
|
#include "main.h"
|
|
#include "rte_wx.h"
|
|
#include "rte_main.h"
|
|
#include "rte_rtu.h"
|
|
|
|
#include "station_config.h"
|
|
|
|
#include <string.h>
|
|
#include <stdio.h>
|
|
|
|
#define INTERFRAME_SP 20
|
|
|
|
|
|
#ifndef _RTU_SLAVE_LENGHT_1
|
|
#define _RTU_SLAVE_LENGHT_1 0x1
|
|
#endif
|
|
|
|
#ifndef _RTU_SLAVE_LENGHT_2
|
|
#define _RTU_SLAVE_LENGHT_2 0x1
|
|
#endif
|
|
|
|
#ifndef _RTU_SLAVE_LENGHT_3
|
|
#define _RTU_SLAVE_LENGHT_3 0x1
|
|
#endif
|
|
|
|
#ifndef _RTU_SLAVE_LENGHT_4
|
|
#define _RTU_SLAVE_LENGHT_4 0x1
|
|
#endif
|
|
|
|
#ifndef _RTU_SLAVE_LENGHT_5
|
|
#define _RTU_SLAVE_LENGHT_5 0x1
|
|
#endif
|
|
|
|
#ifndef _RTU_SLAVE_LENGHT_6
|
|
#define _RTU_SLAVE_LENGHT_6 0x1
|
|
#endif
|
|
|
|
typedef enum rtu_pool_state {
|
|
RTU_POOL_IDLE,
|
|
RTU_POOL_TRANSMITTING,
|
|
RTU_POOL_RECEIVING,
|
|
RTU_POOL_WAIT_AFTER_RECEIVE,
|
|
RTU_POOL_RECEIVE_ERROR,
|
|
RTU_POOL_STOP
|
|
} rtu_pool_state_t;
|
|
|
|
rtu_pool_state_t rtu_pool_state = RTU_POOL_STOP;
|
|
|
|
/**
|
|
* Set to one to switch I/O operations to blocking mode
|
|
*/
|
|
uint8_t rtu_blocking_io = 0;
|
|
|
|
/**
|
|
* Timestamp of last received modbus RTU response with good CRC
|
|
*/
|
|
uint32_t rtu_time_of_last_successfull_comm = 0;
|
|
|
|
/**
|
|
* This variable latches the value of 'rtu_time_of_last_successfull_comm' across
|
|
* consecutive messages with an error status. If the value is the same as during
|
|
* previous transmission the controller is restarted
|
|
*/
|
|
uint32_t rtu_time_of_last_succ_comm_at_previous_error_status = 0;
|
|
|
|
/**
|
|
* CRC value after the last call to rtu_serial_callback
|
|
*/
|
|
uint16_t rtu_serial_previous_crc = 0xFFFF;
|
|
|
|
/**
|
|
* Cleared by 'rtu_serial_callback' when first byte from range 0x1..0xF7 is received
|
|
*/
|
|
uint8_t rtu_waiting_for_slave_addr = 0x1;
|
|
|
|
volatile rtu_pool_queue_t* rtu_used_queue;
|
|
|
|
volatile srl_context_t* rtu_used_serial_context;
|
|
|
|
volatile uint8_t rtu_current_03_slave_address;
|
|
|
|
volatile uint16_t rtu_current_03_base_register;
|
|
|
|
volatile uint8_t rtu_current_03_number_of_registers;
|
|
|
|
/**
|
|
* The callback for stream CRC calculation
|
|
*/
|
|
uint8_t rtu_serial_callback(uint8_t current_data, const uint8_t * const rx_buffer, uint16_t rx_bytes_counter) {
|
|
|
|
uint8_t retval = 0;
|
|
|
|
uint16_t new_crc = 0;
|
|
|
|
// check if the callback still waits for first 'valid' byte to be received from RTU slave
|
|
if (rtu_waiting_for_slave_addr == 0x1) {
|
|
|
|
// check if the byte which was received from the slave is valid address
|
|
if (current_data >= 0x01 && current_data <= 0xF7) {
|
|
// clear this flag to start CRC calculation and data receiving
|
|
rtu_waiting_for_slave_addr = 0;
|
|
}
|
|
else {
|
|
// RTU slave cannot respond with the broadcast address (0x00), also 0xF8..0xFF
|
|
// are not valid RTU address
|
|
;
|
|
}
|
|
}
|
|
|
|
// the second 'if' clause checks if the slave response has began
|
|
if (rtu_waiting_for_slave_addr == 0x0) {
|
|
|
|
// calculate new crc
|
|
new_crc = rtu_crc_stream(rtu_serial_previous_crc, current_data);
|
|
|
|
// if the new CRC value equals 0x0000 it means that this was MSB
|
|
// of CRC from correctly received Modbus-RTU frame
|
|
if (new_crc == 0) {
|
|
// return '1' to terminate the transmission
|
|
retval = 1;
|
|
}
|
|
else {
|
|
rtu_serial_previous_crc = new_crc;
|
|
}
|
|
}
|
|
|
|
return retval;
|
|
}
|
|
|
|
int32_t rtu_serial_init(rtu_pool_queue_t* queue, uint8_t io_mode, srl_context_t* serial_context) {
|
|
|
|
int32_t retval = MODBUS_RET_UNINITIALIZED;
|
|
|
|
// zeroing the content of the structure
|
|
memset(queue, 0x00, sizeof(rtu_pool_queue_t));
|
|
|
|
rtu_blocking_io = io_mode;
|
|
|
|
rtu_used_queue = queue;
|
|
|
|
rtu_used_serial_context = serial_context;
|
|
|
|
#ifdef _MODBUS_RTU
|
|
|
|
#ifdef _RTU_SLAVE_ID_1
|
|
queue->function_id[0] =_RTU_SLAVE_FUNC_1;
|
|
queue->function_parameter[0] = &rte_wx_modbus_rtu_f1;
|
|
|
|
rte_wx_modbus_rtu_f1.slave_address = _RTU_SLAVE_ID_1;
|
|
rte_wx_modbus_rtu_f1.base_address = _RTU_SLAVE_ADDR_1;
|
|
rte_wx_modbus_rtu_f1.number_of_registers = _RTU_SLAVE_LENGHT_1;
|
|
#endif
|
|
|
|
#ifdef _RTU_SLAVE_ID_2
|
|
queue->function_id[1] =_RTU_SLAVE_FUNC_2;
|
|
queue->function_parameter[1] = &rte_wx_modbus_rtu_f2;
|
|
|
|
rte_wx_modbus_rtu_f2.slave_address = _RTU_SLAVE_ID_2;
|
|
rte_wx_modbus_rtu_f2.base_address = _RTU_SLAVE_ADDR_2;
|
|
rte_wx_modbus_rtu_f2.number_of_registers = _RTU_SLAVE_LENGHT_2;
|
|
#endif
|
|
|
|
#ifdef _RTU_SLAVE_ID_3
|
|
queue->function_id[2] =_RTU_SLAVE_FUNC_3;
|
|
queue->function_parameter[2] = &rte_wx_modbus_rtu_f3;
|
|
|
|
rte_wx_modbus_rtu_f3.slave_address = _RTU_SLAVE_ID_3;
|
|
rte_wx_modbus_rtu_f3.base_address = _RTU_SLAVE_ADDR_3;
|
|
rte_wx_modbus_rtu_f3.number_of_registers = _RTU_SLAVE_LENGHT_3;
|
|
#endif
|
|
|
|
#ifdef _RTU_SLAVE_ID_4
|
|
queue->function_id[3] =_RTU_SLAVE_FUNC_4;
|
|
queue->function_parameter[3] = &rte_wx_modbus_rtu_f4;
|
|
|
|
rte_wx_modbus_rtu_f4.slave_address = _RTU_SLAVE_ID_4;
|
|
rte_wx_modbus_rtu_f4.base_address = _RTU_SLAVE_ADDR_4;
|
|
rte_wx_modbus_rtu_f4.number_of_registers = _RTU_SLAVE_LENGHT_4;
|
|
#endif
|
|
|
|
#ifdef _RTU_SLAVE_ID_5
|
|
queue->function_id[4] =_RTU_SLAVE_FUNC_5;
|
|
queue->function_parameter[4] = &rte_wx_modbus_rtu_f5;
|
|
|
|
rte_wx_modbus_rtu_f5.slave_address = _RTU_SLAVE_ID_5;
|
|
rte_wx_modbus_rtu_f5.base_address = _RTU_SLAVE_ADDR_5;
|
|
rte_wx_modbus_rtu_f5.number_of_registers = _RTU_SLAVE_LENGHT_5;
|
|
#endif
|
|
|
|
#ifdef _RTU_SLAVE_ID_6
|
|
queue->function_id[5] =_RTU_SLAVE_FUNC_6;
|
|
queue->function_parameter[5] = &rte_wx_modbus_rtu_f6;
|
|
|
|
rte_wx_modbus_rtu_f6.slave_address = _RTU_SLAVE_ID_6;
|
|
rte_wx_modbus_rtu_f6.base_address = _RTU_SLAVE_ADDR_6;
|
|
rte_wx_modbus_rtu_f6.number_of_registers = _RTU_SLAVE_LENGHT_6;
|
|
#endif
|
|
|
|
#endif
|
|
|
|
return retval;
|
|
|
|
}
|
|
|
|
int32_t rtu_serial_pool(void) {
|
|
|
|
int32_t retval = MODBUS_RET_UNINITIALIZED;
|
|
#ifdef _MODBUS_RTU
|
|
int32_t result = MODBUS_RET_UNINITIALIZED;
|
|
|
|
uint8_t output_data_lenght = 0;
|
|
|
|
rtu_register_data_t* ptr_func_03;
|
|
|
|
// if there were any serial I/O error
|
|
if (rte_rtu_number_of_serial_io_errors > 0) {
|
|
|
|
// check how many serial I/O erros have been detected so far
|
|
if ((rte_rtu_number_of_serial_io_errors % RTU_NUMBER_OF_ERRORS_TO_TRIG_STATUS) == 0) {
|
|
// set the status trigger
|
|
rte_main_trigger_modbus_status = 1;
|
|
|
|
// increment the error counter artificially to protect sending status in the loop
|
|
rte_rtu_number_of_serial_io_errors++;
|
|
|
|
// stupid workaround. If there is a lot of I/O errors reset the controller
|
|
|
|
if (rte_rtu_number_of_serial_io_errors >= (RTU_NUMBER_OF_ERRORS_TO_TRIG_STATUS * 3) ||
|
|
rtu_time_of_last_succ_comm_at_previous_error_status == rtu_time_of_last_successfull_comm)
|
|
{
|
|
rte_main_reboot_req = 1;
|
|
}
|
|
|
|
// latch the current value of last successfull communication
|
|
rtu_time_of_last_succ_comm_at_previous_error_status = rtu_time_of_last_successfull_comm;
|
|
}
|
|
}
|
|
|
|
if (rtu_used_queue->it >= RTU_POOL_QUEUE_LENGHT) {
|
|
rtu_used_queue->it = 0;
|
|
|
|
// all queued modbus functions have been serviced
|
|
rtu_pool_state = RTU_POOL_STOP;
|
|
}
|
|
|
|
switch (rtu_pool_state) {
|
|
case RTU_POOL_IDLE: {
|
|
|
|
// initialize the serial port.
|
|
srl_init( rtu_used_serial_context,
|
|
rtu_used_serial_context->port,
|
|
rtu_used_serial_context->srl_rx_buf_pointer,
|
|
rtu_used_serial_context->srl_rx_buf_ln,
|
|
rtu_used_serial_context->srl_tx_buf_pointer,
|
|
rtu_used_serial_context->srl_tx_buf_ln,
|
|
rtu_used_serial_context->port_baurate,
|
|
rtu_used_serial_context->port_stopbits);
|
|
|
|
// Enabling the timeout for Modbus-RTU.
|
|
// This timeout starts after first received byte and triggers if
|
|
// the slave will hang up and stop the transmission before the end of the frame
|
|
// It doesn't need to be called each time but this is the only function which takes
|
|
// the pointer to serial context
|
|
srl_switch_timeout(rtu_used_serial_context, 1, 0);
|
|
|
|
srl_switch_tx_delay(rtu_used_serial_context, 1);
|
|
|
|
// check the function it at current queue position
|
|
if (rtu_used_queue->function_id[rtu_used_queue->it] == 0x03) {
|
|
// read holding registers
|
|
ptr_func_03 = ((rtu_register_data_t*)rtu_used_queue->function_parameter[rtu_used_queue->it]);
|
|
|
|
rtu_current_03_slave_address = ptr_func_03->slave_address;
|
|
rtu_current_03_base_register = ptr_func_03->base_address;
|
|
rtu_current_03_number_of_registers = ptr_func_03->number_of_registers;
|
|
|
|
// generate request content
|
|
result = rtu_request_03_04_registers(
|
|
1,
|
|
rtu_used_serial_context->srl_tx_buf_pointer,
|
|
rtu_used_serial_context->srl_tx_buf_ln,
|
|
&output_data_lenght,
|
|
rtu_current_03_slave_address,
|
|
rtu_current_03_base_register,
|
|
rtu_current_03_number_of_registers);
|
|
}
|
|
else if (rtu_used_queue->function_id[rtu_used_queue->it] == 0x04) {
|
|
// read input registers
|
|
|
|
// generate request content
|
|
result = rtu_request_03_04_registers(
|
|
0,
|
|
rtu_used_serial_context->srl_tx_buf_pointer,
|
|
rtu_used_serial_context->srl_tx_buf_ln,
|
|
&output_data_lenght,
|
|
((rtu_register_data_t*)rtu_used_queue->function_parameter[rtu_used_queue->it])->slave_address,
|
|
((rtu_register_data_t*)rtu_used_queue->function_parameter[rtu_used_queue->it])->base_address,
|
|
((rtu_register_data_t*)rtu_used_queue->function_parameter[rtu_used_queue->it])->number_of_registers);
|
|
}
|
|
else {
|
|
// any other unsupported or wrong function id. It will also stop at the last element
|
|
// on the last element of the queue
|
|
rtu_pool_state = RTU_POOL_STOP;
|
|
|
|
// rewind the iterator back to the begining
|
|
rtu_used_queue->it = 0;
|
|
|
|
retval = MODBUS_RET_WRONG_FUNCTION;
|
|
}
|
|
|
|
|
|
// if request has been generated correctly
|
|
if (result == MODBUS_RET_OK) {
|
|
|
|
// check if block I/O mode shall be used for the communication
|
|
if (rtu_blocking_io) {
|
|
// call the function which will process the same stuff than
|
|
// RTU_POOL_IDLE (from transmitting), RTU_POOL_TRANSMITTING
|
|
// and partially RTU_POOL_RECEIVING
|
|
result = rtu_serial_blocking_io(rtu_used_serial_context, output_data_lenght);
|
|
|
|
if (result == MODBUS_RET_OK) {
|
|
// if transmission and reception was successful switch to the
|
|
// receiving state. The 'serial_context->srl_rx_state' will be
|
|
// alredy set to 'SRL_RX_DONE'
|
|
rtu_pool_state = RTU_POOL_RECEIVING;
|
|
}
|
|
else {
|
|
rtu_pool_state = RTU_POOL_RECEIVE_ERROR;
|
|
}
|
|
}
|
|
else {
|
|
// trigger the transmission itself
|
|
result = srl_start_tx(rtu_used_serial_context, output_data_lenght);
|
|
|
|
// reset the CRC value to default
|
|
rtu_serial_previous_crc = 0xFFFF;
|
|
|
|
rtu_waiting_for_slave_addr = 1;
|
|
|
|
// if serial transmission has been starter
|
|
if (result == SRL_OK) {
|
|
// proceed to the next state (transmitting)
|
|
rtu_pool_state = RTU_POOL_TRANSMITTING;
|
|
|
|
retval = MODBUS_RET_OK;
|
|
}
|
|
else {
|
|
// if not do nothing and try in next pooler call
|
|
;
|
|
}
|
|
}
|
|
|
|
|
|
}
|
|
else {
|
|
retval = MODBUS_RET_REQUEST_GEN_ERR;
|
|
}
|
|
|
|
break;
|
|
}
|
|
case RTU_POOL_TRANSMITTING: {
|
|
|
|
// if transmission is still pending
|
|
if (rtu_used_serial_context->srl_tx_state == SRL_TXING || rtu_used_serial_context->srl_tx_state == SRL_TX_WAITING) {
|
|
// wait until it will finish
|
|
;
|
|
}
|
|
else {
|
|
// trigger reception
|
|
srl_receive_data_with_callback(rtu_used_serial_context, rtu_serial_callback);
|
|
|
|
// enable the timeout in case the RTU slave won't respond
|
|
// at all or there is no slaves connected to RS485 bus
|
|
srl_switch_timeout_for_waiting(rtu_used_serial_context, 1);
|
|
|
|
// switch the state
|
|
rtu_pool_state = RTU_POOL_RECEIVING;
|
|
|
|
}
|
|
|
|
retval = MODBUS_RET_OK;
|
|
|
|
break;
|
|
}
|
|
case RTU_POOL_RECEIVING: {
|
|
|
|
// if data reception still took place
|
|
if (rtu_used_serial_context->srl_rx_state == SRL_WAITING_TO_RX || rtu_used_serial_context->srl_rx_state == SRL_RXING || rtu_used_serial_context->srl_rx_state == SRL_RX_IDLE) {
|
|
// wait
|
|
;
|
|
}
|
|
else if (rtu_used_serial_context->srl_rx_state == SRL_RX_DONE) {
|
|
// parse the response from RTU slave // here there is a problem with changing slave address
|
|
if (rtu_used_queue->function_id[rtu_used_queue->it] == 0x03 || rtu_used_queue->function_id[rtu_used_queue->it] == 0x04) {
|
|
result = rtu_parser_03_04_registers(
|
|
rtu_used_serial_context->srl_rx_buf_pointer,
|
|
rtu_used_serial_context->srl_rx_bytes_counter,
|
|
((rtu_register_data_t*)rtu_used_queue->function_parameter[rtu_used_queue->it]),
|
|
&rte_rtu_last_modbus_exception);
|
|
}
|
|
else {
|
|
retval = MODBUS_RET_WRONG_FUNCTION;
|
|
}
|
|
|
|
// check parsing result
|
|
if (result == MODBUS_RET_OK) {
|
|
// store the current time
|
|
rtu_used_queue->last_successfull_call_to_function[rtu_used_queue->it] = main_get_master_time();
|
|
|
|
// switch the state to inter-frame silence period
|
|
rtu_pool_state = RTU_POOL_WAIT_AFTER_RECEIVE;
|
|
}
|
|
else if (result == MODBUS_RET_GOT_EXCEPTION) {
|
|
// in case of an excetpion store the current timestamp
|
|
rte_rtu_last_modbus_exception_timestamp = main_get_master_time();
|
|
|
|
// switch the state to inter-frame silence period
|
|
rtu_pool_state = RTU_POOL_WAIT_AFTER_RECEIVE;
|
|
}
|
|
else {
|
|
// Receive error state will switch to the next function
|
|
rtu_pool_state = RTU_POOL_RECEIVE_ERROR;
|
|
}
|
|
|
|
// get current time to start the inter-frame delay
|
|
rtu_time_of_last_successfull_comm = main_get_master_time();
|
|
|
|
rte_rtu_number_of_successfull_serial_comm++;
|
|
|
|
// Close the serial port. This is a part of the stupid workaround of the problem
|
|
// with a serial port which leads to receiving a lot of idle frames of unknown origin
|
|
// and corrupting some part of data at the begining of some Modbus-RTU frames
|
|
srl_close(rtu_used_serial_context);
|
|
|
|
}
|
|
|
|
// in case of any error during data reception or the serial driver have fallen into unknown & unexpected
|
|
// state
|
|
else {
|
|
|
|
rtu_pool_state = RTU_POOL_RECEIVE_ERROR;
|
|
|
|
srl_close(rtu_used_serial_context);
|
|
}
|
|
|
|
break;
|
|
}
|
|
case RTU_POOL_WAIT_AFTER_RECEIVE: {
|
|
|
|
// check if required interframe silence period elapsed
|
|
if (main_get_master_time() - rtu_time_of_last_successfull_comm > INTERFRAME_SP) {
|
|
rtu_pool_state = RTU_POOL_IDLE;
|
|
|
|
rtu_used_queue->it++;
|
|
}
|
|
break;
|
|
}
|
|
case RTU_POOL_RECEIVE_ERROR: {
|
|
// if the response from the slave was corrupted or any other serial I/O error
|
|
// occured switch to the next function in the queue
|
|
rtu_pool_state = RTU_POOL_IDLE;
|
|
|
|
// increasing the global counter of io errors
|
|
rte_rtu_number_of_serial_io_errors++;
|
|
|
|
rte_rtu_last_modbus_rx_error_timestamp = main_get_master_time();
|
|
|
|
// icrease the error counter for this queue element
|
|
rtu_used_queue->number_of_errors[rtu_used_queue->it] = rtu_used_queue->number_of_errors[rtu_used_queue->it] + 1;
|
|
|
|
// move to the next function queued
|
|
rtu_used_queue->it++;
|
|
|
|
retval = MODBUS_RET_OK;
|
|
|
|
break;
|
|
}
|
|
case RTU_POOL_STOP: {
|
|
break;
|
|
}
|
|
default: {
|
|
rtu_pool_state = RTU_POOL_STOP;
|
|
break;
|
|
}
|
|
}
|
|
#endif
|
|
return retval;
|
|
}
|
|
|
|
int32_t rtu_serial_blocking_io(srl_context_t* serial_context, uint8_t query_ln) {
|
|
|
|
int32_t retval = MODBUS_RET_UNINITIALIZED;
|
|
|
|
uint8_t serial_result = SRL_UNINITIALIZED;
|
|
|
|
// reset the CRC value to default
|
|
rtu_serial_previous_crc = 0xFFFF;
|
|
|
|
rtu_waiting_for_slave_addr = 1;
|
|
|
|
// sending data
|
|
serial_result = srl_start_tx(serial_context, query_ln);
|
|
|
|
// if tx has been triggered successfully
|
|
if (serial_result == SRL_OK) {
|
|
|
|
// wait for transmission to complete
|
|
srl_wait_for_tx_completion(serial_context);
|
|
|
|
// trigger reception
|
|
serial_result = srl_receive_data_with_callback(serial_context, rtu_serial_callback);
|
|
|
|
if (serial_result == SRL_OK) {
|
|
|
|
// enable the timeout in case the RTU slave won't respond
|
|
// at all or there is no slaves connected to RS485 bus
|
|
srl_switch_timeout_for_waiting(serial_context, 1);
|
|
|
|
// wait for the slave response
|
|
srl_wait_for_rx_completion_or_timeout(serial_context, &serial_result);
|
|
|
|
if (serial_result == SRL_OK) {
|
|
retval = MODBUS_RET_OK;
|
|
}
|
|
else {
|
|
retval = MODBUS_RET_GOT_EXCEPTION;
|
|
}
|
|
}
|
|
|
|
}
|
|
|
|
return retval;
|
|
}
|
|
|
|
int32_t rtu_serial_start(void) {
|
|
|
|
int32_t retval = MODBUS_RET_UNINITIALIZED;
|
|
|
|
rtu_pool_state = RTU_POOL_IDLE;
|
|
|
|
return retval;
|
|
}
|
|
|
|
int32_t rtu_serial_get_status_string(rtu_pool_queue_t* queue, srl_context_t* srl_ctx, char* out, uint16_t out_buffer_ln, uint8_t* generated_string_ln) {
|
|
|
|
int32_t retval = MODBUS_RET_UNINITIALIZED;
|
|
int string_ln = 0;
|
|
|
|
memset(out, 0x00, out_buffer_ln);
|
|
#ifdef _MODBUS_RTU
|
|
|
|
string_ln = snprintf(out, out_buffer_ln, ">MT %X, LRET %X, LSCT %X, NSSC %X, NSE %X, RXB %X, RXI %X, TXB %X",
|
|
main_get_master_time(),
|
|
rte_rtu_last_modbus_rx_error_timestamp,
|
|
rtu_time_of_last_successfull_comm,
|
|
(int)rte_rtu_number_of_successfull_serial_comm,
|
|
(int)rte_rtu_number_of_serial_io_errors,
|
|
srl_ctx->total_rx_bytes,
|
|
srl_ctx->total_idle_counter,
|
|
srl_ctx->total_tx_bytes);
|
|
|
|
*generated_string_ln = (uint8_t) string_ln;
|
|
#endif
|
|
return retval;
|
|
}
|
|
|