kopia lustrzana https://github.com/erdewit/HiFiScan
Add section about causality
rodzic
193a378187
commit
b887a4db66
31
README.rst
31
README.rst
|
@ -7,11 +7,11 @@ The goal of HiFiScan is to help equalize an audio system to get
|
|||
the best possible audio quality from it.
|
||||
There are two ways to do this:
|
||||
|
||||
1. Manual: The realtime frequency spectrum is displayed and
|
||||
1. Manual: The realtime frequency response is displayed and
|
||||
the peaks and troughs can be interactively equalized away.
|
||||
|
||||
2. Automatic: The frequency response is measured and a correction
|
||||
is calculated. This correction is a phase-neutral finite impulse
|
||||
is calculated. This correction is by default a phase-neutral finite impulse
|
||||
response (FIR) that can be imported into most equalizer programs.
|
||||
|
||||
The measuring is done by playing a "chirp" sound that sweeps
|
||||
|
@ -96,7 +96,7 @@ and then "Load"):
|
|||
.. image:: images/Convolver.png
|
||||
|
||||
We go back to the spectrum measurement and store the uncorrected
|
||||
spectrum with the "Store" button (to compare with later measurements).
|
||||
spectrum with the **Store** button (to compare with later measurements).
|
||||
More measurements can be stored as well, for example where the microphone
|
||||
is placed in different locatations, The total average of the stored
|
||||
measurements is shown in orange
|
||||
|
@ -277,6 +277,31 @@ and in cyan the reshaped spectrum that tries to follow the target curve:
|
|||
.. |License| image:: https://img.shields.io/badge/license-BSD-blue.svg
|
||||
:alt:
|
||||
|
||||
Causality
|
||||
---------
|
||||
|
||||
The default is to create a phase-neutral (aka linear-phase)
|
||||
impulse response. It's also possible to create a minimum-phase response.
|
||||
Even everything in between is possible. This is done with the **Causality**
|
||||
parameter, where 0% is phase-neutral and 100% is minimum-phase.
|
||||
Varying the causality smoothly transitions between the extremes:
|
||||
|
||||
.. image:: images/causality-waveform.png
|
||||
|
||||
The latency decreases proportional to the causality.
|
||||
At 100% the response becomes zero-latency and purely causal, where only the current
|
||||
and later sound samples are used. The pre-echo is eliminated at the price of
|
||||
twice the post-echo.
|
||||
Note that despite the name of "minimum-phase"
|
||||
this setting actually incurs the most phase distortion, which can get severe with
|
||||
a steep equalization.
|
||||
|
||||
A good compromise may be a causality of 40%, which reduces the pre-echo
|
||||
by about 6 dB while not phase-smearing too much.
|
||||
Let your ears be the judge of what sounds best.
|
||||
|
||||
A tool for changing the causality of existing impulse responses (as WAV file)
|
||||
is found in "Tools... -> Change IR causality".
|
||||
|
||||