Quirks, known bugs, and other notes.
====================================
In this document I'll try to describe the behavior of the Idiom Press
Rotor-EZ and RotorCard interfaces as well as the HyGain DCU-1/DCU-1X control
units with Hamlib. For background information see rotorez/rotorez.txt.
The Idiom Press interfaces are the most capable of the units supported by
this backend and all available commands are supported by these units at this
time. The HyGain control units only support a subset of the command set
involving rotor positioning.
This document is organized by Hamlib function calls and documents observed
behavior with each call.
rot_set_position
* Fractional values passed for azimuth are dropped. i.e. 180.6 becomes
180 while a value greater than 359.4999 is converted to 0 for DCU1/
DCU-1X compatibility.
* Allowed range for azimuth is 0 to 360.
* Values passed for elevation are ignored. The protocol only supports
azimuthal positioning
rot_get_position
* Position reading is returned in whole degrees from 0 to 359.
* Not supported by DCU-1/DCU-1X.
rotorez_rot_stop
* Causes immediate cessation of rotor positioning.
* Not supported by DCU-1/DCU-1X.
rot_set_conf
* Accepts one of E, e, J, j, O, o, S, and s (see rotorez/rotorez.txt)
in *val.
* The value in token is not used by the backend and may be safely
set to TOK_BACKEND_NONE.
* Not supported by DCU-1/DCU-1X.
BUGS
Please report all bugs to <hamlib-developer@users.sourceforge.net>