kopia lustrzana https://github.com/Hamlib/Hamlib
Add calibration table for TS-890S RFPOWER_METER_WATTS
Make sure we only get RFPOWER_WATTS during xmit, and STRENGTH during receive; else return -RIG_ENAVAIL.pull/1501/head
rodzic
d9bae6f46f
commit
4ef5bd4142
|
@ -292,6 +292,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
case RIG_LEVEL_RFPOWER_METER_WATTS:
|
||||
{
|
||||
cal_table_float_t *table;
|
||||
ptt_t ptt;
|
||||
/* Values taken from the TS-890S In-Depth Manual (IDM), p. 8
|
||||
* 0.03 - 21.5 MHz, Preamp 1
|
||||
*/
|
||||
|
@ -311,6 +312,20 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
{48, 20}, {59, 40}, {70, 60}
|
||||
}
|
||||
};
|
||||
static cal_table_t power_meter =
|
||||
{
|
||||
7, { { 0, 0}, { 5, 5}, { 10, 10}, {19, 25},
|
||||
{ 35, 50}, { 59, 100}, { 70, 150}
|
||||
}
|
||||
};
|
||||
|
||||
/* Make sure we're asking the right question */
|
||||
kenwood_get_ptt(rig, vfo, &ptt);
|
||||
if ((ptt == RIG_PTT_OFF) != (level == RIG_LEVEL_STRENGTH))
|
||||
{
|
||||
/* We're sorry, the number you have dialed is not in service */
|
||||
return -RIG_ENAVAIL;
|
||||
}
|
||||
/* Find out which meter type is in use */
|
||||
retval = kenwood_safe_transaction(rig, "EX00011", ackbuf, sizeof(ackbuf), 11);
|
||||
|
||||
|
@ -345,7 +360,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
|
||||
if (level == RIG_LEVEL_RFPOWER_METER_WATTS)
|
||||
{
|
||||
val->f = round(val->i / 70.0 * 150);
|
||||
val->f = rig_raw2val(val->i, &power_meter);
|
||||
}
|
||||
else
|
||||
{
|
||||
|
|
Ładowanie…